background image

i

Q

2003 S 

SPECIFICATIONS

VOLTAGE

220

v

  

Single Phase

HOSE INLET 

DIAMETER

1

qty @

4" 

2

qty @

6"

AMPERAGE

15

Amps

MAX AIR FLOW

1700

CFM

MOTOR POWER

3

hp

MAX STATIC 

PRESSURE

8" H

2

0

POWER CABLE

10

ft

FILTER AREA

144

sq ft

FAN WHEEL 

13.5"

dia

 × 2.5"

w

FILTER TYPE

Polyester

WEIGHT

400

lbs

DUST CAPACITY

1.5

cu ft

DIMENSIONS

35"

w

 × 44"

l

 × 64"

h

NOISE LEVEL

83

d

b a

i

Q

2007 T 

SPECIFICATIONS

VOLTAGE

480

v

  

Three Phase

HOSE INLET 

DIAMETER

1

qty @

4" 

2

qty @

6"

AMPERAGE

9.2

Amps

MAX AIR FLOW

4000

CFM

MOTOR POWER

7.5

hp

MAX STATIC 

PRESSURE

8" H

2

0

POWER CABLE

10

ft

FILTER AREA

144

sq ft

FAN WHEEL 

15"

dia

 × 5"

w

FILTER TYPE

Polyester

WEIGHT

430

lbs

DUST CAPACITY

1.5

cu ft

DIMENSIONS

35"

w

 × 44"

l

 × 64"

h

NOISE LEVEL

85

d

b a

i

Q

2013 G 

SPECIFICATIONS

VOLTAGE

Gas Honda 

GXV390

HOSE INLET 

DIAMETER

1

qty @

4" 

2

qty @

6"

AMPERAGE

N/A

MAX AIR FLOW

4000

CFM

MOTOR POWER

13

hp

 elec. start

MAX STATIC 

PRESSURE

8" H

2

0

POWER CABLE

N/A

FILTER AREA

144

sq ft

FAN WHEEL 

15"

dia

 × 5"

w

FILTER TYPE

Polyester

WEIGHT

430

lbs

DUST CAPACITY

1.5

cu ft

DIMENSIONS

35"

w

 × 44"

l

 × 64"

h

NOISE LEVEL

85

d

b a

Patented 

i

QSmartTable

 

  

collects dust as you cut

Long-lasting polyester filters with 

manual shaker handle

Fork tube base with available 

casters for portability

Easy-to-use dust  

collection drawer

Heavy-duty dust collection system for 20" & 24" 

masonry saws. Dry cut masonry, concrete and  

stone products with no dust and no wet cutting 

problems.

24385 Nandina Ave. Suite B, Moreno Valley, CA  92552 

888-274-7744

 • 

i

QPowerTools.com

No more wet cutting

Slurry, stained product and swpp’s: never 

think about them again

Saves time and money 

The time and money spent on dust or slurry 

management and cleanup: it’s yours again

Gas or electric powered

Versatility on the job site: move the cutting 

to the most efficient location, inside or out

Summary of Contents for 2003 S

Page 1: ...sical injury or damage to equipment Personal Protective Equipment Respirator Safety Glasses Ear Plugs etc Should Be worn at all time when Operating or Servicing The Dust Collection Vacuum and Related Equipment Model iQ 2000 Series Dust Collector with manual shaker USER S MANUAL For Gas powered units refer to Honda Operators Manual for motor servicing and operation ...

Page 2: ...x 2 13 x 5 13 x 5 Weight LB 400 430 400 Max Air Flow CFM 1700 4000 4000 Max Static Pressure INCH H O 8 8 8 Filter Area SQ FT 144 Polyester 144 Polyester 144 Polyester Noise Level dB A 83 85 83 Hose Inlet Diameter INCH 1 4 2 6 1 4 2 6 1 4 2 6 Size W x L x H 35 x 35 x 64 35 x 35 x 64 35 x 35 x 64 Dust Capacity Cubic Ft 1 5 1 5 1 5 2 Specifications For Gas powered units refer to Honda Operators Manua...

Page 3: ...2 P003 Dust Tray 4 IQ2 P004 Fork Tube Base 5 IQ2 P005 Dust Tray Gasket 6 IQ2 P006 Filter Element Assembly 7 IQ2 P007 Manual Shaking Handle 8 IQ2 P008 Main Door Gasket 9 IQ2 P009 Door Knob 10 IQ2 P010 Grab Bar 13 IQ2 P013 Auxiliary Cap 1 2 3 4 5 6 7 8 9 10 12 PARTS LIST Model iQ 2000 3 ...

Page 4: ...el Line IQ13G P007 12V Battery IQ13G P008 Throttle Mount Plate IQ13G P009 Fuel Tank IQ13G P010 Fan 13 1 2 X 5 CW IQ13G P011 Fan Housing with Motor Plate IQ13G P012 Motor Push Start Button IQ13G P013 Battery Cable iQ 2013G IQ 2007T PART DESCRIPTIONS IQ7T P001 7 5 HP 460V Three Phase Motor IQ7T P002 Fan 13 1 2 X 5 CW IQ7T P003 Fan Housing with Motor Plate IQ7T P004 Manual Motor Starter with Adjustab...

Page 5: ... not vacuum weld ing fumes burning cigarettes ashes matches or other similar materials 7 Never operate the unit in the presence of flammable vapors aerosol products or near the spraying of flammable liquids i e paints and oils 8 Do not operate the unit without the filter tubes in place 9 Lock option casters in place when unit is in operation or storage 10 Dust bucket release handle must be in upri...

Page 6: ...ft to ensure that unit will remain stationary on surface 4 Prepare for Transport Moving and lifting unit by forklift Verify that the unit is not plugged into power source main door and dust bucket must be secure and cast ers locked Align forklift with fork tubes on the base of the unit precede forward until fork is securely inserted in tubes Lift unit to an adequate height in order to remove caste...

Page 7: ...forward h Remove and set aside all hitch pin clips from the filter hanger assembly i Slide all filters tubes off the filter hanger assembly and properly dispose of all used filter tubes j Replace with new filter tubes k Reassemble by reversing these steps 2 Lubrication No lubrication is necessary However certain parts of the vacuum as sembly are subject to wear and should be replaced as necessary ...

Page 8: ...air or replacement of defective parts and reserves the right to determine whether the failure is due to defective material work manship or other causes Failures caused by alteration or misuse are not covered by the warranty All warranty repairs must be done by IQ Power Tools or an authorized service representative Any repair to the equipment other than by these authorized facilities voids this war...

Page 9: ...Built with You in Mind Heavy duty dust collection system for 20 24 masonry saws iQSmartTable Dry cut masonry products dust free Patented iQSmartTable ...

Page 10: ... A MAX AIR FLOW 4000CFM MOTOR POWER 13hp elec start MAX STATIC PRESSURE 8 H20 POWER CABLE N A FILTER AREA 144sq ft FAN WHEEL 15 dia 5 w FILTER TYPE Polyester WEIGHT 430lbs DUST CAPACITY 1 5cu ft DIMENSIONS 35 w 44 l 64 h NOISE LEVEL 85db a Patented iQSmartTable collects dust as you cut Long lasting polyester filters with manual shaker handle Fork tube base with available casters for portability Ea...

Reviews: