STATUS
Information message: Request for basic
status: output power socket status,
temperature and GSM signal
TurnedOFF, TEMP:
25C, Signal: 35 %
Ctrl
THERMOSTAT=YES Activates temperature monitoring
THERMOSTAT=YES
– OK
Ctrl
THERMOSTAT=NO
Deactivates temperature monitoring
THERMOSTAT=NO
– OK
Ctrl
TEMPON=XX
Temperature limit for turning on of output
power socket – if temperature threshold is
reached or passed
TEMPON=XX – OK
Ctrl
TEMPOFF=XX
Temperature limit for turning off of output
power socket – if temperature threshold is
reached or passed
TEMPOFF=XX – OK Ctrl
THERMOSTAT?
Information message: Request for
temperature configuration
THERMOSTAT=YES,
(NO) ON=25
OFF=27
Ctrl
7.1 Thermostat
This feature can be attractive if you wish to ensure activating or deactivating
appliance when temperature threshold is reached.
Typical example is heating activation when temperature is below 20 ˚C and
deactivating when temperature is over 25 ˚C.
(THERMOSTAT=YES, TEMPON=20, TEMPOFF=25)
Other example is airconditioning activation over 28 ˚C and deactivation when
temperature is below 24 ˚C
(THERMOSTAT=YES, TEMPON=28, TEMPOFF=24)
7.2 Temperature calibration
Measured temperature is usually influenced by heating caused by IQsocket
electronics , so built-in thermometer provides usually little higher temperature
as real. For this reason is used temperature calibration constant which is
configured based on global experience to value 4. This calibration can be
changed individually for each monitored environment. Measured temperature is
decreased always by calibration this constant.
Command
Description
Response
Type
TEMPCAL=X
Changes calibration constant. 1
– 9 values can be used.
TEMPCAL = X – OK
Conf
TEMPCAL?
Request for TEMPCAL config.
TEMPCAL = 4
Conf
8.Other commands
Command
Description
Response
Type
ERRORREPLY=YES
Activates sending of information SMS
for each received SMS command,
which was not executed due to any
error.
ERRORREPLY =YES – OK
Conf