2009 NETCONS, s.r.o.
Page 14 of 16
Command
Description
Response
Type
DATE
Automatic date/time configuration from
SMS is activated
DATE yy/mm/dd,
hh:mm:ss+zz –
OK
Conf
DATE=yy/mm/dd,hh:
mm:ss+zz
Used for manual date/time configuration DATE=yy/mm/dd,
hh:mm:ss+zz –
OK
Conf
DATE?
Resuest for actual date/time
DATE yy/mm/dd,
hh:mm:ss+zz
Conf
NOTE: zz is GMT timezone
11. Scheduler
Scheduler enables to control output power socket automatically based on pre-
scheduled date/time rules. Scheduler accept max. 8 rules.
Command
Description
Response
Type
SChh:mm,da
y,action
Add new rule for specified time valid for
all days within a week
SChh:
mm,*,ON – OK
Ctrl
SCHEDULER-hh:mm
Delete record for configured time
SCHEDULER-
hh:mm - OK
Ctrl
SCHEDULER?
Request for scheduler configuration
hh:mm,*,action
Ctrl
* = any day
1=Monday, 2=Tuesday, 3=Wednesday, 4=Thursday, 5=Friday, 6=Saturday, 7=Sunday
Actions: ON=Turn On, OFF=Turn off, INF=status of IQsocket is sent (as by STATUS command)
AON=Alarm On, AOF=Alarm Off
Examples:
SC10:00,*,ON
Every day at 10:00 is output power socket turned on
SC14:30,*,OFF
Every day at 14:30 is output power socket turned off
SC01:00,1,AON
Every Monday at 01:00 is activated alarm
SC02:00,2,AOF
Every Tuesday at 02:00 is deactivated alarm
SC18:00,5,INF
Every Friday at 18:00 is sent status info
12. Original settings
Each new device is preconfigured with factory default values. Device can be
anytime returned back to these default values during it’s lifecycle. This can be
realized by reset to factory default procedure.
12.1 Reset to factory default procedure
Reset button is available on the bottom cover near the SIM slot, details can be
found in first pages of this document.
Please push this reset button at least 5 seconds, then release. All LED
indicators should start blinking for next 10 seconds. Please press the button
again within these 10 seconds to confirm reset to factory default procedure.
After this step is your device in original factory configuration.