2009 NETCONS, s.r.o.
Page 15 of 16
12.2. Default factory settings
Parameter
Value/Status
Parameter
Value/Status
Output power socket OFF
SMSPIN
NOPIN
Mikrorelay/output2
OFF
OUTPUT
REMEMBER
INPUT
ALARMHIGH
RESTARTTIME
10
ERRORREPLY
NO
RING
NOACTION
ALARMOUTPUT
10
SECNUMBER
NO
ALARM
OFF
SMSWWW
NO
TEMPCAL
4
SMSCONFIRM
YES
ALERT
RINGON
RINGCONFIRM
NO
DATE
AUTOMATIC
THERMOSTAT
NO
SCHEDULER
EMPTY
TEMPON
25
TEMPALARM
NO
TEMPOFF
20
13. Firmware upgrade
IQsocket firmware upgrades can be performed only by authorised trained
person or by authorised service center.
14. LED indicators
POWER
LIGHTS RED
Input power is OK;
BLINKS RED 4 x WITHIN SECOND
Alarm detection is active
LIGHTS GREEN
Alarm is detected while detection is active
BLINKS GREEN 4 x WITHIN SECOND
Alarm is detected, detection is not active
BLINKS RED 2 x PER SECOND
SIM is not correctly inserted or missing
GSM
BLINKS GREEN, EACH 3 SECONDS
Logged to GSM network
BLINKING GREEN EACH SECOND
Not logged to GSM network yet, searching
LIGHTS GREEN 2 x PER SECOND
SIM card have active PIN usage
RELAY
NOT ACTIVE
Output power socket is OFF
LIGHTS YELLOW
Output power socket is ON
BLINKS YELLOW
Hardware error
POWER
Indication of input power
GSM
Indication of GSM login status
RELAY
Indication of output power status
BE CAREFULL!
This step will erase all your IQsocket configuration.