4.2 Managing output power socket by phone call 

Output power socket can be managed also by call using by mobile phone or 

fixed phone. In such a case – power socket runs some action immediately. 
Action can be output power interruption (appliance reboot), negating output 

power socket status or other action. Action must configured in advance. 
 

 

 

Message 

Description 

Response 

Type 

RING=SWITCH 

If this parameter is configured, 
status of output power socket is 
changed (negated) by phone call. 

RING=SWITCH – OK 

Conf 

RING=RESTART 

If this parameter is configured, 
output power socket is turned on 
for time configured by RESETTIME 
parameter. 

RING=RESTART – OK 

Conf 

RING=NOACTION   

No action is performed on phone 
call 

RING=NOACTION – OK  Conf 

RING? 

Information message: Request for 
ring action configuration 

RING=(NOACTION),RE
START,SWITCH 

Conf 

RESTARTTIME=XX 

Configures time in seconds for 
RESTART action. Maximal number 
is 180. 

RESTARTTIME=XX – 
OK 

Conf 

RESTARTTIME? 

Information message: Request for 
RESTARTTIME configuration 
parameter 

RESTARTTIME=30 

seconds

 

Conf 

 

4.3 Controlling output power socket manually 

Output power socket can be managed also manually by hidden button on 

bottom side near the SIM slot. Button can be activated by suitable thin 
mechanic tool. Pressing this button causes switching output power socket to 
negative value. 

5. Security features 

Product can be configured for advanced security to disable control of the power 

socket by unauthorized persons. Power socket uses two security methods: 
 

 

Allowing only authorized phone numbers 

 

Authentication by password/SMSPIN number 

 
In case of first option – device will ignore all SMS and calls from unauthorized 

phone numbers. If security is not configured, anyone who knows SIM card 
calling number can control power socket remotely. Power socket uses security 

lists for this purpose. This list supports 7 phone numbers max. 

NOTE:

 Configuration commands are accepted only within first 10 minutes 

after intelligent power socket is plugged in. It is from security reasons. 

Configuration SMS messages are typed by Bold.

 

 

Summary of Contents for IQSW-GSM

Page 1: ...User guide www IQsocket eu Intelligent power sockets IQsockettm WALL IQSW GSM makes your life more comfortable User Guide IQSW GSM documentation v1 1 4 R1 for firmware v1 1 4 ...

Page 2: ...ttings for SMS commands 9 6 2 Confirmation settings for phone calls 9 7 Measuring temperature 9 7 1 Thermostat 10 7 2 Temperature calibration 10 8 Other commands 10 9 Alarms and microrelay 11 9 1 External detector alarms 11 9 2 Temperature alarms 12 9 3 Generated alerts 12 9 4 Alarm logs 13 9 5 External detectors scheme 13 9 6 Microrelay scheme 13 10 Date and time 13 11 Scheduler 14 12 Original se...

Page 3: ...our homes or weekend holiday houses 2 Product description Intelligent power socket IQsocket IQSW GSM helps to control any appliance remotely over GSM network using by mobile phone IQSW GSM is managed by SMS messages or phone call It can work also as a independent thermo regulator because of integrated thermometer which control appliance by turning on off according to preconfigured temperature rule...

Page 4: ...for external detectors generating alarms Microrelay Switched contact by microrelay SIM socket Socket for SIM card Push push type Manual button Used to turn on off output power socket manually or reset product to default values Temperature sensor Provides temperature data Detail of temperature sensor Temperature sensor measure environmental temperature and provide it over SMS on request Output powe...

Page 5: ...into wall socket 230V Indicators will start blinking in few seconds then basic test is started for 10 seconds If all is OK red POWER indicator is turned on GSM indicator is blinking periodically green light while searching GSM networks after it s logged blinking every 3 seconds RELAY indicator should light on off if output power socket in turned on off Product is ready now for your use 4 Managing ...

Page 6: ...cket and microrelay are turned off TurnedOFF Ctrl TURNON Output power socket and microrelay are turned on TurnedON Ctrl TURNOFF1 Output power socket is turned off TurnedOFF1 Ctrl TURNON1 Output power socket is turned on TurnedON1 Ctrl TURNOFF2 Microrelay is turned off TurnedOFF2 Ctrl TURNON2 Microrelay is turned on TurnedON2 Ctrl TURNOFF 123 Output power socket is turned off for 123 minutes Maxima...

Page 7: ...ARTTIME XX OK Conf RESTARTTIME Information message Request for RESTARTTIME configuration parameter RESTARTTIME 30 seconds Conf 4 3 Controlling output power socket manually Output power socket can be managed also manually by hidden button on bottom side near the SIM slot Button can be activated by suitable thin mechanic tool Pressing this button causes switching output power socket to negative valu...

Page 8: ...PIN xxxx OK Conf SMSPIN NOPIN Using of password SMSPIN is deactivated SMSPIN NOPIN OK Conf SMSPIN Request for SMSPIN configuration SMSPIN NOPIN 1234 Conf SMSWWW YES Controlling by SMS from Internet is allowed SMSWWW YES OK Conf SMSWWW NO Controlling by SMS from Internet is disabled SMSWWW NO OK Conf SMSWWW Request for SMSWWW configuration SMSWWW NO Y ES Conf 5 2 Security list Security list allow c...

Page 9: ...turned on for all SMS commands SMSCONFIRM YES OK Conf SMSCONFIRM NO SMS confirmation is turned off for all SMS commands SMSCONFIRM NO OK Conf SMSCONFIRM Request for SMS confirmation settings SMSCONFIRM NO Y ES Conf 6 2 Confirmation settings for phone calls Command Description Response Type RINGCONFIRM YES Phone call confirmation is turned on for all commands Hang off after 10 seconds RINGCONFIRM Y...

Page 10: ...on when temperature is below 20 C and deactivating when temperature is over 25 C THERMOSTAT YES TEMPON 20 TEMPOFF 25 Other example is airconditioning activation over 28 C and deactivation when temperature is below 24 C THERMOSTAT YES TEMPON 28 TEMPOFF 24 7 2 Temperature calibration Measured temperature is usually influenced by heating caused by IQsocket electronics so built in thermometer provides...

Page 11: ...In this case alarm is generated after low voltage is detected INPUT ALARMLOW OK Conf INPUT Information message Request for input mode configuration INPUT DISCONNECTED CONNECTED Conf VERSION Request for firmware version Ver 1 0 6 c 2008 Ctrl RINGON Back call is realized to the number of the incoming SMS Usefull feature when using prepaid cards to keep card active no confirmation Ctrl If bad command...

Page 12: ...erature alarms are disabled TEMPALARM NO OK Ctrl TEMPALARM MAX In case of maximal temperature threshold is reached SMS is sent TEMPALARM MAX OK Ctrl TEMPALARM MIN In case of minimal temperature threshold is reached SMS is sent TEMPALARM MIN OK Ctrl TEMPALARM MIX In case of mini or maximal temperature threshold is reached SMS is sent TEMPALARM MIX OK Ctrl TEMPALARM Request for temperature configura...

Page 13: ...Command Description Response Type SHOWALARM Used to list alarm history log yy mm dd hh ss Ctrl This feature can be also used for example to monitor people activity in room In case of active ALARMON you can also switch to ALARMOFF by manual button on device After this manual command you can use manual button under normal operation not switching back to ALARMON More detectors can be used in parallel...

Page 14: ...off INF status of IQsocket is sent as by STATUS command AON Alarm On AOF Alarm Off Examples SCHEDULER 10 00 ON Every day at 10 00 is output power socket turned on SCHEDULER 14 30 OFF Every day at 14 30 is output power socket turned off SCHEDULER 01 00 1 AON Every Monday at 01 00 is activated alarm SCHEDULER 02 00 2 AOF Every Tuesday at 02 00 is deactivated alarm SCHEDULER 18 00 5 INF Every Friday ...

Page 15: ...indicators POWER LIGHTS RED Input power is OK BLINKS RED 4 x WITHIN SECOND Alarm detection is active LIGHTS GREEN Alarm is detected while detection is active BLINKS GREEN 4 x WITHIN SECOND Alarm is detected detection is not active BLINKS RED 2 x PER SECOND SIM is not correctly inserted or missing GSM BLINKS GREEN EACH 3 SECONDS Logged to GSM network BLINKING GREEN EACH SECOND Not logged to GSM net...

Page 16: ...te power turnon turnoff of output circuit up to 48V Remote power turnoff for specified time Remote appliance restart Remote appliance status switch turnon to turnoff or back Remote temperature measuring Thermometer Alarm detection Scheduler Power 230V CEE 7 7 Weight Netto Brutto 350g 420g Operating temperature 10 to 50 C 16 Care and security recommendations Product was designed for indoor use Don ...

Reviews: