2008 NETCONS, s.r.o.
Page 5 of 7
IQsocket is switched into monitoring mode 10 minutes after it is
powered on.
5. Default values
Each new device is preconfigured with default parameters.
5.2. Default values
Parameter
Value
Output power
ON
WATCHDOG
ON
ECHO
OFF
6. Firmware upgrade
Firmware upgrade can be performed only by authorised specialist or by
authorised service center.
7. LED lights
POWER/ACT
CHANGING RED AND GREEN
5 minutes from socket is turned on
LIGHTS GREEN
Output power is ON
LIGHTS RED
Output power is OFF
POWER/ACT
Indicator of output power socket status and
data activity
8. Technical specification
Model
IQSW-RS232-F, IQSW-RS232-E
Input power plug
230V / 50Hz , CEE 7/7
Output power socket
230V , CEE 7/4 German "Schuko" earthed
230V, CEE 7/4 French type
Data interfaces
RS232 , DB9 connector
Power switching
Output power: Relay, 230V/16A (2s), 10A long-term