©2016 IQtronic technologies Europe, s.r.o.
Page 15 of 22
Set control by diference
- An input control based on differences in the values
of two sensors.
Operated is only output 2. Suitable for example for solar sets.
From the description it is clear that, if the difference T1-T2 is higher than 8
degrees, then the output 2 turns on. When the temperature difference falls
by 4 degrees, then turns off. The output relay contacts are switchable so it
is possible an inverse connection.
Set control by terms
- Operation using user-defined conditions. Hysteresis
are here given by the difference between maximum and minimum value. For
each output you can set its own condition.
Programable OUTPUT 1,
An automatic control of output 1 by the scheduler,
or equithermal table / curve.
With every type it is possible to insert up to 30 lines regardless of the choice
of
Scheduler / Ekvitherm.
You can only choose one of them. The entries
for both will not be overwritten and remain saved. They are always displayed
after option selection and confirming by the
Save
button.
Scheduler
It works only after obtaining a valid time from the NTP server.
Each inserted row indicates a change to the set temperature for a given time.
Example:
Keep a temperature of 25°C every day after 14:35 , and 10.5°C after 22:00.
Insert line:
Mo,Tu,We,Th,Fr,Sa,Su,14:35,25.0 press the
Save
button
Mo,Tu,We,Th,Fr,Sa,Su,22:00,10.5 press the
Save
button
If the lines are entered correctly they will be displayed in the main window.