Syntax is : -20.3:5.5 or 10.5:35.0 , where the first temperature before the 
colon is the temperature EXT (external temperature, based on which is then 
maintaining the temperature INT) after the colon is the temperature of the 
internal (INT) - maintained in the given area. 

Temperatures outside of inserted points are calculated by linear extrapolation. 
Values above the maximum or below the minimum are extrapolated. 

 

Deletion we will perform by inserting the text "ALL" and pressing the Delete 
key or by a text containing a row for deletion. 

 
 
 

 

 

 

 

4

 

Use of the button DEF 

 

By briefly pressing a button on the the board we switch the output relay. If the 
button is held down for more than 4 seconds and then released, all LEDs will 
start flashing for 10 seconds. In case of further pressing during the blinking, 
the device will reset to factory settings

 
 

5

 

Software 

5.1 Utility IQlocator.exe 

The program is used to quickly locate the device on a network, change its IP 
address and to upload new software updates - upload firmware. 

The connected device is found after running the programs and pressing the 
SCAN button.  
 
 
 
 

Note:

 The device shown warning in status red line in case  of wrong user 

input . 

Summary of Contents for IQTB-TC840

Page 1: ...m Intelligent power sockets IQsocket IQTB TC840 makes your life more comfortable User guide Double IP thermometer thermostat hygrometer hygrostat with datalogger and scheduler based on user s conditio...

Page 2: ...3 1 Setting device parameters 10 3 3 Utility 12 3 2 SNMP MIB table 12 3 5 Description of connectors and board 13 3 6 Set output menu for setting the output relays manually automatically by the schedul...

Page 3: ...for full functionality Do not repair a damaged product by yourself and send it to the manufacturer s diagnostics Improper wiring and short circuits on board connections may lead to permanent damage o...

Page 4: ...rd DS18B20 with a range of 55 to 125 degrees C 3 Integrated temperature sensor on a board of the device 4 LED indicators for displaying output states 5 Passive POE RJ45 with wide range power supply fr...

Page 5: ...d LED blinks at intervals of 1 sec regular operation ETH Green LED sby shining indicates connection to Ethernet By dimming indicates its activity GND 0VDC potential for sensors yellow wire yellow pin...

Page 6: ...ry power But must not exceed 40VDC It s also possible to power it via a passive POE directly from the Ethernet connector The power scheme using the passive POE device After connecting to voltage will...

Page 7: ...device is 192 168 0 100 Start the Web browser with a default ip In case of using an alias NetBIOS name IQTB TC840 3 1 Displaying current values The page will display all data the current state of the...

Page 8: ...ch change the counter will increase by one By clicking on the inputs rectangle we display the temperature history there have values in the graph the same course and they only serves as an example of d...

Page 9: ...e graph there are also minimum and maximum values marked by a black triangle Visualization of data larger interval such as the season has resulted in a smaller display selection of values without aver...

Page 10: ...s r o Page 10 of 22 It is also possible to set by a filter minimums and maximums for displaying the graph If offsets are set to 0 then they will not apply and the graph is displayed whole from min to...

Page 11: ...ata and also convert Sensor 1 2 ID sensor ID by default 0 for DS18B20 For other types is mentioned in the application data sheet for a given sensor such as relative humidity sensor 1 etc SNMP option f...

Page 12: ...lt factory default settings Reboot ip board Device restart The device starts with changed values if the user changed them Upload upload new device firmware update Clear values clear min max of the val...

Page 13: ...a from sensors that may be displayed by superior system such as PRTG as illustrated in the following picture 3 5 Description of connectors and board For quick orientation in the wiring is possible to...

Page 14: ...setting the output relays manually automatically by the scheduler by conditions differentially or equithermal table Set automatic control easiest and fastest setup of level monitoring By using hyster...

Page 15: ...an set its own condition Programable OUTPUT 1 An automatic control of output 1 by the scheduler or equithermal table curve With every type it is possible to insert up to 30 lines regardless of the cho...

Page 16: ...day after 00 00 and each Wednesday 10 5 C after 22 00 Mo 00 00 25 0 press the Save button We 22 00 10 5 press the Save button Meaning of abbreviations Mo Monday Tu Tuesday We Wednesday Th Thuersday Fr...

Page 17: ...and pressing the Delete key or by a text containing a row for deletion 4 Use of the button DEF By briefly pressing a button on the the board we switch the output relay If the button is held down for...

Page 18: ...fter pressing the button SET IP addresses we can temporarily change the IP address for configuration directly in the device using a Web browser Also check the firewall settings because they might succ...

Page 19: ...er alia the TRAP packet receiver After inserting the basic data such as Read Community etc and enabling SNMP option in the Device settings by default it is enabled we can read through specific OID val...

Page 20: ...3 OID 1 Set UNIX timeticks 0 1 3 6 1 4 1 21287 26 19 0 GAUGE value For the conversion of time to UNIX value you can use the calculator directly from the device s website and confirm 1 Set VALUE 0 1 3...

Page 21: ...s way For feedback control of data is for each value after the separator the displayed serial number of reading If the value is not available returns N A 7 Reading using XML format file status xml sta...

Page 22: ...ML and WEB Double thermostat hygrostat Advanced programmable automatic control based on conditions of the scheduler equiterm and difference Dimensions 72x50mm Weight 0 035 kg netto Operating temperatu...

Reviews: