User Manual BMM-1716
All technical values are subject for changes w/o further notifications
IRENIS GmbH © 2021
Statement /
Anmerkungen:
Text and pictures herein are subject to changes w/o notifications.
The user manual will be updated in real time without special notice.
This user manual is provided only as a reference guide for technicians as examples.
All parameter data are examplesonly.
User adjustableparameters are freely selectable.
Menu views can vary slightly depending on the software version & the operability does not change as a result.
The images in this manual are for illustrative purposes only.
Alle Parameterangaben sind lediglich beispielhaft.
Technisch realisierbare Parameter sind frei wählbar.
Menüansichten können je nach Software-Stand leicht variieren; die Bedienbarkeit ändert sich dadurch nicht.
Die Bilder in dieser Anleitung dienen lediglich als Illustrationen.
The SAT IF switch matrix can be mounted into a 19“ rack or on a wall, by using the wall adaptor.
The environmental temperature may not exceed 55 °C. The main power should be disconnected for any work on the device.
The device must be grounded according to EN 60728-11 standard. The insulation of the grounding cable should be stripped
down approximately 15 mm and the cable must be fixed by using the grounding screw designated on the device.
NOTE:
After a power failure, all configured data are kept & stored in a non-volatile memory.
All assembly and connection work must be carried out before the unit is connected to the mains voltage supply!
Observe the safety instructions.
The SAT IF signals and the terrestrial signal must be fed into the corresponding connections on the back of the
de-vice using suitable cables. The output connectors are located at the front panel.
Once all signal cabling has been connected, the power supply cable can be connected and the device will
switch on. The operating status is indicated by LEDs on the front panel.
NOTE
At delivery, identical network parameters are set for all devices. The setup and configuration of several devices
within a network should therefore be carried out with each unit connected one at a time securing not to overlap
the device IP addresses.
The unit can be reset to its delivery network configuration and access data status at any time using a specific
reset operation. Firstly, remove the power plug from the mains. Then press and hold the button
Reset
, located
at the rear side of the device and reconnect the power plug to the mains. After a short time, the status LED next
to the button flashes red/green and the button can then be released. The network parameters will now be set to
the values shown in the following table.
Default settings (Factory settings):
Network*
IP Address
Subnet mask
Gateway
Web management port
Login Username:
Login Password:
192.168.1.128
255.255.255.0
192.168.0.1 *
80
admin
password
Activated outputs
OUT 1 - OUT 16
OUT 1, 5, 9, 13 to IN 1
OUT 2, 6, 10, 14 to IN 2
OUT 3, 7, 11, 15 to IN 3
OUT 4, 8, 12, 16 to IN 4
* Please adjust the Gateway address according to the routing settings in your network