QPSK/IP DEMODULATOR
7.4.5 Factory Settings
All the user configurable parameters will be set to the factory default settings, including IP address and
the unit name. Note the unit will not be connected with the HDMS remote management system until
the IP is properly configured.
7.4.6 Optional Function
This menu is protected by password, type in 900000 to the menu. There are two submenus:
External Board Type:
Press
<ENTER>-key
to active the menu, use < > < >-keys to configure the
TS/IP functional block as
‘IP In’ or ‘IP Out’ or ‘No Exist’, and the option is exclusive. Press
<ENTER>-
key
to confirm or to scrap by pressing
<EXIT>-key
.
After the operation, you need reboot the unit to valid the configuration.
IP In:
the TS/IP port is configured as input, you can feed transport stream over IP into the unit. The
menu
‘Ethernet’ will be showed under the inputs menu.
IP Out:
the TS/IP port is configured as output, you can set the transport stream over IP output to
the IP network. The menu
‘Ethernet’ will be showed under the outputs menu.
No Exist:
the TS/IP port is invalid. Therefore the menu
‘Ethernet’ will not be showed anywhere.
Filter Function:
Press <ENTER>-key to active the menu, use < > < >-keys to configure the Mux/Filter
functional block as
‘Mux’ or ‘Filter’ or ‘Disable’. Press <ENTER>-key to confirm or to scrap by pressing
<EXIT>-key.
7.4.7 Setting Machine Type
This setting is reserved for factory-setting, and you are not allowed to access this menu.
FAQ
1. Why is there nothing in the LCD?
Answer: Please check whether the power supply is connected well first. If not, insert it well and turn on
the device. If there is still nothing displayed on the LCD, then the unit may be damaged, please contact
the agent for technical support.
2. Why can the QPSK/QAM/COFDM/DVB-S2 signal not be locked?
Answer: Please ensure whether the input cable in connected well first. If not, insert it well. If it is
connected well, please check whether all the necessary parameters are set properly. If not, please set
the parameters properly. If the signal still cannot be locked, please check whether the quality of the
signal is out of the threshold of the Tuner. If not, then the device
m
ight be damaged, please contact the
agent for support.
3. Why can the ASI not be locked?
Answer: Please make sure the BNC cable is connected well and there are programs transmitted to the
u
nit via the BNC cable.
4. Why can the This equipment
-x
not be connected to HDMS?
Answer: Please ensure whether the Ethernet cable is connected well first. Make sure the parameters
are set appropriately under
“Local Setup”. Check the whether HDSM software is installed correctly in
PC which should be also set appropriately and can access the network the This equipment
-
x
connected.