IRMA6-SENSOR-HD-00-SWITCH-(IO)-00-(R)(1)
Installation Manual | Released
Rev. 1.4 | 12/2020
17
/ 27
In the section “Door /Function Area” you set the:
•
“Function Area Address”
•
with the “FA” according to real door / fa number in vehicle
•
“Door Address”with the setting value which is, as a rule, identical to the
“Function Area Address” (FA) in an Ethernet installation; and
•
“Door Close Delay” with the value of the time determined between the door
closing signal sent by the on-board computer and the actual mechanical
closing of the door.
In the section “Status LEDs” you set “OFF”, as this is the default LED setting of the
sensor.
In the section “Installation Parameter” you set the parameters
for the placement of IRMA 6 according to the measures in the vehicle.
Measure the values for each installation parameter in the vehicle
and enter them. (See graphics below for each installation parameter
in vehicle).