background image

IPU 40060 Issue 9 

 

 2004 InfraRed Integrated Systems Ltd  

 

 

 

Page 1 of 27 

IRISYS 

Universal Thermal 

Imager 

Type IRI 1011

 

 
 

 
 

User Manual 

 

 
 
 

Safety Warning: 

 

The  equipment  described  in  this  document  uses  a  Class  II  laser.    Under  no  account 
should  anyone  look  directly  into  the  laser  beam  or  the  laser  beam  exit  aperture, 
irreversible  damage  to  the  eye  may  occur.    The  laser  should  not  be  operated  when 
there are personnel in the imager’s field of view. 
 
Caution – use of controls or adjustments or performance of procedures other than 
those specified in this document may result in hazardous laser radiation exposure. 

 

InfraRed Integrated Systems Ltd 

Park Circle, Tithe Barn Way, 

Swan Valley, 

Northampton, 

NN4 9BG 

Tel: (0) 1604 594200 

Fax: (0) 1604 594210 

Email: sales@irisys.co.uk 

 

Conforms to USA 21 CFR 
1040.10. 
Class II laser product.

 

 

Summary of Contents for IRI 1011

Page 1: ...re irreversible damage to the eye may occur The laser should not be operated when there are personnel in the imager s field of view Caution use of controls or adjustments or performance of procedures...

Page 2: ...GER WITH A PALM 12 2 4 1 Setting up the Palm with the IRI 1011 Thermal Imager 12 2 4 1 1 Installing the IRISYS 1011 Imager software onto a Palm 12 2 4 1 2 Switching off the Palm s automatic shutdown 1...

Page 3: ...hows where the on off button is 2 Open up the battery compartment on the bottom of the IRI 1011 Thermal Imager by sliding the battery cover off 3 Carefully remove the battery holder and insert 4 AA si...

Page 4: ...et PC Palm should be switched on approximately 2 minutes before use This is to allow the internal electronics to warm up and stabilise so as to achieve optimum performance The mains power supply inclu...

Page 5: ...ermal Imager Safety notice The laser used in this device is designated Class II Under no circumstances should personnel look straight into the laser Components of the IRI 1011 Thermal Imager The IRI 1...

Page 6: ...run Microsoft Pocket PC 2000 2002 or 2003 see Section 2 3 3 for recommended Pocket PC s The Pocket PC can be used to display process and store snapshots of thermal images 1 Ensure that ActiveSync is i...

Page 7: ...lowed to fully discharge the imager software will be lost and must be re installed either from memory storage or from the CD again The Pocket PC uses power even when it is switched off Regular recharg...

Page 8: ...set the path directory to which snapshot images are saved Ambient o C The user can set the ambient temperature if the emissivity see below is not given the value of 1 the software compensates for the...

Page 9: ...e The user can select a displayed resolution of 16x16 pixels or 96x96 pixels 2nd Element The user can select whether to have the second SP2 temperature cursor displayed on the screen Continuous Auto S...

Page 10: ...ty and pressing left right adjusts the temperature range 2 Selected Temperature Cursor SP1 The SP1 cursor can be moved around the screen on the thermal image by using the Navigation Action button i e...

Page 11: ...sys co uk Please note that it is necessary to acquire the appropriate synchronization cable for a specific Pocket PC The URL links provided in Table 1 for cable suppliers are intended as an example Fo...

Page 12: ...m display iii A new window will open on your Palm stating whether it is set up for a Local or Modem connection Make sure Local is selected iv Press the HotSync button on your cradle cable or on the Pa...

Page 13: ...software from the Palm website http palmsource palmgear com index cfm fuseaction software showsoftware SID 5290900C CF18 AC90 838C210BE1658BDE PartnerREF prodID 1499 6 Double click on the AlwaysOn prc...

Page 14: ...e mode Pressing Yes will save the image with the name Snapshot n snp where n is the next available number in the sequence Also the snapshot will be labelled with the date and time at which it was save...

Page 15: ...achieve the accuracy of temperature readings see note 3 in Section 3 1 Colour Map The user can select one of three possible colour options o Greyscale o Red Blue o Green Blue Integration The number o...

Page 16: ...hermal image by using the Navigation Action button i e up down left right When the Auto adjust is ON pressing the Nav Action button will cycle between the two temperature cursors only and not the manu...

Page 17: ...ided Launch the IRISYS 1011 Imager program from the Desktop icon or from START PROGRAMS IRISYS IRISYS 1000 Series Imager When launched the window obtained will be similar to Figure 12 On initial launc...

Page 18: ...o Fahrenheit or Kelvin Integration sets the number of frames to integrate up to ten maximum Figure 12 Thermal Imager launch window Adjusting the displayed Thermal Image The sensitivity and range can...

Page 19: ...bmp file Snapshot takes a snapshot of the image and saves it as a scene data file The View menu allows the following Toolbar Turn the Tool Bar on and off Status Bar Turn the Status Bar on and off Con...

Page 20: ...n a different colour To read the temperature of a cursor use the mouse to click on the corresponding oval colour as displayed in the temperature display window see Figure 14 The temperature graph plot...

Page 21: ...erature measurements The camera should be positioned so that the item of interest appears within this area of the display Caution Do not adjust the lens focus The lens is fixed focus and factory set 3...

Page 22: ...2 Open up the handle grip below the fastening clips 3 Un clip the cable connector cover 4 Detach the cover and put it to one side 5 Connect the serial synchronization cable into 6 Thread the other end...

Page 23: ...rotated to 10 Example with the clip around the wrong accommodate different Pocket PC models way it may cover the Pocket PC power button 11 Example with the clip around the correct 12a Note the locato...

Page 24: ...place the RS232 connector cover 16 Line up the holes on the back of the imager with the pegs on the handle 17 Push the imager down onto the pegs so 18 Coil up the serial synchronization cable so that...

Page 25: ...ations 4 1 2 Preparing the Handle for use with a Palm PC Pocket PC Palm Cable cover Cable cover 1 Pocket PC Palm 2 Remove the Pocket PC hooks by unscrewing Hooks Hooks the two screws from the front of...

Page 26: ...40060 Issue 9 Page 26 of 27 4 1 3 Removing the Imager from the Handle 1 Locate the release lever 2 Press the release lever down 3 Keeping the release lever pressed down remove the imager from the han...

Page 27: ...ct Details IRI 1011 Thermal Imager Serial Number This can be found printed on the label near RS232 port Pocket PC Palm and PC Software Version installed Software version number can be found whilst sof...

Reviews: