7. OPERATING CONDITIONS

Ambient temperature: -30…40°C. 
Humidity: ≤ 98% at 25°C.
When  operating  under  non-recommended  conditions,  device  parameters  can  deviate  from 
specified values.   

8.  PACKAGE CONTENTS

-

MATRIX

 

III MF-I

 Reader:  ........1

-Plugs: ......................................2
-Screws 3x30:  ..........................2
-Wall Plugs: ..............................2

9.  LIMITED WARRANTY 

This Device is covered by limited warranty for 2

4

 months.

The warranty becomes void, if:
-  this Manual's guidelines are not followed;
-  the device has suffered physical damage;
-  the device has visible traces of exposure to moist and/or aggressive chemicals;
-  the device circuits have visible traces of tampering by unauthorised parties. 
Under this warranty, the Manufacturer shall repair the device or replace any broken parts as 
required, free of charge, in cases where the fault is caused by a Manufacturer's defect.  

page 5

MATRIX III MF-I

www.ironlogic.

me

Summary of Contents for Matrix III MF-I

Page 1: ...allasTouch Memory protocol up to 15 m using Wiegand protocol up to 100 m Card reading status indication buzzer bicoloured LED Indication control internal external Power supply voltage 12 V DC Current in Card Standby mode up to 40 mA Dimensions 118 x 45 x 22 mm 3 MOUNTING AND CONNECTION The reader should be mounted on a flat surface in a place allowing unimpeded token access to the reader To mount ...

Page 2: ...yellow LED G green to the common ground terminal GND black Fig 1 Choosing the transmission protocol Fig 2 Device Dimensions DATA1 GND D0 DATA0 D1 GND D0 iButton D1 GND D0 iButton D1 IButton One time transmission Wiegand IButton DS1990A emulation ACS controller Reader GND GND GND screw 118 mm 82 mm 22 mm Table 1 Reader wires designation page 2 MATRIX III MF I www ironlogic me 45 mm Wire Colour Wire...

Page 3: ...s in Unprotected mode transmitting to the controller the UIDs of all the access cards it could read 5 1 1 Entering Protected Mode 1 On an unpowered reader connect DATA0 white and LED R yellow terminals See Fig 1 2 Power on the reader 3 If the LED is blinking red and a signal is sounding the reader already is in Protected Mode 4 If the LED is shining solid red approach the reader with an IronLogic ...

Page 4: ...ive parameter value when it is sounding connect LED G green and GND black terminals 5 Power off the reader To adjust another parameter power on the reader again 6 3 Configuration via RS 485 Configuration via an RS 485 link is done by RdConf software see www ironlogic me website and a Z 397 Guard connector 1 Connect the reader to an RS 485 connector a DATA0 white to A b DATA1 brown to B c GND black...

Page 5: ...arranty for 24 months The warranty becomes void if this Manual s guidelines are not followed the device has suffered physical damage the device has visible traces of exposure to moist and or aggressive chemicals the device circuits have visible traces of tampering by unauthorised parties Under this warranty the Manufacturer shall repair the device or replace any broken parts as required free of ch...

Page 6: ...E mail info ironlogic lv headstaff ironlogic lv Phone 37166181894 37124422922 www ironlogic me The symbol of crossed throught waste bin on wheels means that the product must be disposed of at f separate collection point This also applies to the product and all accessories marked with this symbol Products labeled as such must not be disposed of with normal household waste but should be taken to a c...

Reviews: