background image

4.3. Add Master Cards (1m, 1M)

Touch the reader with a Master card (short touch). On touch, the controller issues a short beep 
acknowledging the Master card; then within 6 s touch and hold the Master card at the reader 
(long touch). On touch, the reader issues two short beeps denoting the second Master card 
touch in programming mode, and in 6 s, a beep acknowledging Add Master Cards mode. Now 
remove the Master card from the reader.
To add more Master cards, keep touching the reader with them one after another, with intervals 
between touches ≤16 s. Each new card touch is acknowledged by the reader with a short beep. 
If a card is already stored in memory as a Master card, no signals are issued. Exit from this 
mode happens automatically, in 16 s after the last touch. The reader confirms exit with a series 
of five short beeps.

4.4. Erase Normal Cards with a Master Card (2m, 1M)

Touch the reader with a Master card twice (short touches). On first touch, the reader issues a 
short beep acknowledging the Master card. On second touch, the reader issues two short 
beeps, denoting the second Master card touch in programming mode;then within 6 s touch and 
hold the Master card at the reader (long touch). On third touch, the reader issues three short 
beeps, and in 6 s, a beep indicating transition to Erase Normal Cards mode. Now remove the 
Master card from the reader.
To erase cards, touch the reader with them one after another, with intervals between touches ≤ 
16 s. Each card touch is acknowledged with a short beep. If the card was not present in 
memory, two short beeps sound. Exit from this mode happens either automatically, in 16 s after 
the last touch, or after a Master card touch. The reader confirms the exit with a series of five 
short beeps.

4.5. Erase All Memory (3m, 1M)

Touch the reader with a Master card three times (short touches). On first touch, the reader 
issues a short beep acknowledging the Master card. On second touch, the reader issues two 
short beeps, denoting the second Master card touch in programming mode. On third touch, the 
reader issues three short beeps, denoting the third Master card touch, and within 6 s touch and 
hold the Master card at the reader (long touch). On fourth touch, the reader issues four short 
beeps, and in 6 s, another series of short beeps, indicating the erasure of entire reader memory 
and exit from the programming mode. Now remove the Master card from the reader; the 
Programming mode will be automatically re-entered after next power-up.
Note: When erasing the whole database using a Master card, the programmed Door Release 
Time is NOT reset.

4.6. Programming Door Release Time (4m)

Touch the reader with a Master card four times. On each touch, the controller issues beeps 
acknowledging the Master card touches, their number corresponding the number of touch. So 
on fourth touch, the controller issues four beeps and enters the Door Release Time 
Programming mode. Within 6 s after the last touch, turn down the internal lock handle and hold 
it for the exact time you want to set as door release time. During door release time programming 
the blue LED will keep flashing. When the lock handle is released, the controller issues a beep 
and stores the measured time into its memory.

page 7

Z-8 EHT 

www.ironlogic.

me

Summary of Contents for Z-8 EHT

Page 1: ...Cards Special Cards which are assigned specific access rights and offer protection against card cloning or loss The Hotel Mode operates only with special software 2 SPECIFICATIONS Work Frequency 125 kHz Keys standards EM Marine HID ProxCard II Atmel T5557 Maximum number of keys cards 1364 Maximum Event Log capacity 1000 Inbuilt NVRAM Present Reading Distance 2 4 cm Standby mode current 30 µA Power...

Page 2: ...sembly does not imply screwing the star shaped fixing screw with significant effort this will lead to no leeway for the lock handles So use fixing liquid or super glue before installing the star shaped fixing screw Details you can see on Fig 1 3 2 Changing the lock direction left right door In factory configuration the mechanical lock comes set to use with a right hand door To install the lock ont...

Page 3: ... 3 Z 8 EHT www ironlogic me left hand right hand Fig 1 Fig 1 1 Fig 1 3 Fig 1 2 www ironlogic ru latch 1 2 A droplet of glue The black triangle marker must always point towards the latch as shown on Fig 1 3 ...

Page 4: ...al cover Plastic inlay Fig 4 Internal lock cover External lock cover Reader Fig 3 Rod 8х27 Fig 2 Screw 5х55 Z 8 EHT www ironlogic me 123 0 88 0 24 0 Screw 4х25 A B Requirements for the door dimensions A 40 50 mm B min 100 mm Reader Socket Power socket ...

Page 5: ...tore a Master card While the beeps are still sounding within 16 s approach a card to the reader this card will be stored into lock s memory as a Master card The beeps will cease confirming that the first Master card was successfully stored To add more Master cards approach them one by one to the reader keeping the interval between cards less than 16 s Each touch by a new card the reader will confi...

Page 6: ...ch is acknowledged by a short beep If a card is already present in memory two short beeps are issued Exit from this mode happens either automatically in 16 s after the last touch or after a Master card touch The reader confirms the exit with a series of five short beeps 4 2 Add Blocking Cards 1M InAdd Normal Cards mode touch your card to the reader and hold for 9 s until a long beep i e a short be...

Page 7: ...ot present in memory two short beeps sound Exit from this mode happens either automatically in 16 s after the last touch or after a Master card touch The reader confirms the exit with a series of five short beeps 4 5 Erase All Memory 3m 1M Touch the reader with a Master card three times short touches On first touch the reader issues a short beep acknowledging the Master card On second touch the re...

Page 8: ...ouch the reader with a Master card the exit is acknowledged with a series of short beeps Note In case of power failure activated Accept mode will stay on after the power is back 4 9 Free Pass Mode Handle Down 1B In the Free Pass mode the lock becomes permanently open This mode allows keeping the door open in emergencies or for a certain time period working day break conference etc To enter the Fre...

Page 9: ...card The doors the card may open Software Hotel USB 6 X1 SOCKET JUMPERS DESIGNATION The X1 socket is installed on the reader s Printed Circuit Board PCB X1 socket allows setting the lock logic mode and editing the lock s keys memory The lock is supplied with a jumper its different positions on the X1 socket activate different lock functions see Fig 5 Position 1 changes the lock operational logic i...

Page 10: ...will survive batteries replacement 7 FIRMWARE UPDATE The lock s firmware can be updated or replaced via Lock Commander software Z 2 USB RF 1996 adapter is also required to download the new firmware into the lock Depending on the firmware and model the lock can operate Stand alone without software Stand alone with software The firmware available for the lock can be found at the www ironlogic me web...

Page 11: ... duration 3 s The door release timer can be programmed within 0 220 seconds See Paragraph 4 6 Z 2 USB RF 1996 adapter The Z 2 USB RF 1996 adapter transfers data in a contactless way between the lock and a PC via the reader antenna It also can update the lock s firmware At the bottom of adapter s case a sticker denotes its antenna position To transfer the data approach the adapter s antenna to the ...

Page 12: ...rom the locks in OFFICE mode in a contactless way through the lock s reader To support all the details of card issuing process and lock operation in HOTEL mode Base Z5R software To create delete and edit keys in the database on a PC and to transfer them to from the locks in OFFICE mode via the X1 socket Hotel software To work with the locks in HOTEL mode To issue and edit guests cards staff cards ...

Page 13: ...WARRANTY This Device is covered by limited warranty for 24 months The warranty becomes void if this Manual s guidelines are not followed the device has suffered physical damage the device has visible traces of exposure to moist and or aggressive chemicals the device circuits have visible traces of tampering by unauthorised parties Under this warranty the Manufacturer shall repair the device or rep...

Page 14: ...Riga Latvia E mail info ironlogic lv headstaff ironlogic lv Phone 37166181894 37124422922 www ironlogic me The symbol of crossed throught waste bin on wheels means that the product must be disposed of at f separate collection point This also applies to the product and all accessories marked with this symbol Products labeled as such must not be disposed of with normal household waste but should be ...