Terminations/Spark Arrestor
Fireplace system must be terminated with
listed round top or chase terminations. In any
case, refer to installation instructions supplied
with termination. Terminations approved for
this fireplace are RT-8DM and RTL-8DM that
can be used for flashing or chase and ET-
8DM, ETO-8DM, ETL-8DM and ETLO-8DM
for chase style termination only. Figure 19
shows an RTL-8DM round top termination.
CAUTION: Do not seal open-
ings on the rooftop flashing. Fol
-
low the installation instructions
provided with the termination
being used.
Terminations with 16" slip pipe sections are
available. RTT-8DM and RTTL-8DM are
approved for flashing installations. When
needed, these adjustable terminations may
be used in combination with pipe assembly
to achieve correct chimney height.
Note: In rare instance there is a problem with
side driven rain or wind or chimney is not draft-
ing properly, an ADS-8DM (Anti-Draft Shield)
can be used with round terminations.
VEntInG InStaLLatIOn
Continued
Attach Bracket
Tabs to
Outer Pipe
(3 Places)
Secure with
Screws
RTL-8D
Level of
Flue Gas
Outlet
Caulk
Collar
Flashing
Underlap Shingles
Bottom Only
Figure 19 - Termination
Overlap
Shingles Top
and Sides
VENTING INSTALLATION USING 8"
B-TYPE VENTING SYSTEM
Transition pipe model BTC-8 and starter collar
are shown in Figure 20. Remove starter collar
and set aside. Slide transition pipe over vent
collar and attach with a minimum of 4 screws.
Replace starter collar over transition pipe and
attach using 4 screws located on leg stands.
To install b-vent piping, slide first piece of
b-vent over transition pipe and attach with
either a minimum of 3 screws or other means
approved by the vent manufacturer.
B-Vent Piping
Transition Pipe
Model BTC-8
Starter Collar
Vent Collar
Figure 20 - Installing Transition Pipe and
Starter Collar
CHECKING FOR PROPER VENTING
After completing and checking electrical, gas
and vent connections, follow the lighting in-
structions and allow the main burner to run for
approximately 5 minutes. Hold a lighted match
near the top edge of fireplace opening and play
it along entire length of opening (see Figure 21,
page 17). Proper venting should tend to draw
the flame or smoke into the appliance. Improper
venting or escaping of spillage of burned gas, is
indicated when the match flickers or goes out.
If the appliance is found to be improperly
venting, shut it off and notify your installer
or a qualified service agency to inspect the
venting system.
NOTICE: This appliance is
equipped with a vent safety
shutoff switch which will shut
down the appliance in the case of
a venting problem. Do not bypass
the vent safety switch. If the appli
-
ance should shut down, contact a
qualified installer, service agency
or your gas supplier to have the
vent inspected before operating.