page
9
9. SAFE DEPOSIT BOX MODE
Note: Cannot select an operational mode without a Master key.
Rules of operations for
Safe
Deposit Box mode
.
1. The latch is always released (OUT), if the database is not empty;
2. Opening the lock is possible by
swip
ing ALL the keys to the reader, one after another.
3. After all keys have been presented, a beep sounds and the LED flashes
green, the lock's
latch is withdrawn for 3 s and then is popped back out. If the door was locked, it's opened
by a lock's push bolt.
4. If a key not present in memory is
swipe
d, a beep sounds and the LED flashes
red.
Z-
395
EHT
www.ironlogic.
me
Action
Sound
LED
Latch
What for
Add Normal Keys
Default state
None
None
OUT
Waiting for Normal key recording
Swipe Master key 1
st
time
R blink
IN
Entering Edit Normal Keys mode
Swipe Master key 2
nd
time
R blink
OUT
Entering Edit Normal Keys mode
Swipe Master key 3
rd
time
for 6 s
R
IN
Entering Edit Normal Keys mode
Swipe 1
st
, 2
nd
, 3
rd
, …, Max
(24
th
) keys
G
IN
Storing Normal Key into the controller
Swipe Master key
R blink
OUT
Exiting Add Normal Keys mode
After 10 s
R blink
OUT
Erase All Normal Keys
Default state
None
None
OUT
Waiting for Normal key written
Swipe Master key 1
st
time
R blink
IN
Entering Edit Normal Keys mode
Swipe Master key 2
nd
time
R blink
OUT
Entering Edit Normal Keys mode
Swipe Master key 3
rd
time
for 6 s
R
IN
Entering Edit Normal Keys mode
Press button once
R
OUT
Erase All Normal keys
Swipe Master key
R blink
OUT
Exiting Erase All Normal Keys mode
After 10 s
R blink
OUT
Master key override
The door closed, swipe
Master key
R blink
IN
Master key override, locker opening
Wait 10 s
R blink
OUT
Default state