GROUND MOUNT INSTALLATION MANUAL - 2
© 2019 IRONRIDGE, INC. VERSION 2.8
RATINGS
MARKINGS
Product markings are located on the system’s Rail
Connectors.
UL 2703 LISTeD
• Conforms to STD UL 2703 (2015) Standard for Safety First Edition: Mounting Systems, Mounting Devices, Clamping/
Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels.
•
Certified to CSA STD LTR AE-001-2012 Photovoltaic Module Racking Systems.
• Max Overcurrent Protective Device (OCPD) Rating: 25A
• Max Module Size: 25.6 ft²
• Max Frameless Module Size for Canadian LTR-AE: 21.5 ft²
•
CAMO Specific Allowable Design Load Rating: 50 PSF downward, 50 PSF upward, 15 PSF lateral
• LTR AE Canadian Load Rating: 2400 Pa
• System Level Allowable Design Load Rating: meets minimum requirements of the standard (10 PSF downward, 5
PSF upward, 5 PSF lateral). Actual system structural capacity is defined by PE stamped
CLASS A SYSTeM FIRe RATING PeR UL 2703
• Not Fire Rated
STRUCTURAL CeRTIFICATION
•
Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7
#5003225