Rails with Integrated Grounding

Installation Manual

Warranty Information

Effective for IronRidge, Inc. (“IronRidge”) mounting structure components (“Products”) manufactured after 

April 1st, 2012, IronRidge provides the following warranties, for Products installed properly and used for the 

purpose for which the Products are designed:

 

• finishes shall be free of visible defects, peeling, or cracking, under normal atmospheric conditions, for 

 

  a period of three (3) years from the earlier of (i) the date of complete installation of the Product or (ii) 

 

  thirty days after the original purchaser’s date of purchase of the Product (“Finish Warranty”);

 

• components shall be free of structurally-related defects in materials for a period of ten (10) years 

 

  from the earlier of (i) the date of complete installation of the Product or (ii) thirty days after the original 

 

  purchaser’s date of purchase of the Product; 

 

 

• components shall be free of functionally-related manufacturing defects for a period of twenty (20) 

 

  years from date of manufacture. 

The Finish Warranty does not apply to: (a) surface oxidation of the galvanized steel components or any foreign residue deposited on 

Product finish; and (b) Products installed in corrosive atmospheric conditions, as defined solely by IronRidge; corrosive atmospheric 

conditions include, but are not limited to, conditions where Product is exposed to corrosive chemicals, fumes, cement dust, salt water 

marine environments or to continual spraying of either salt or fresh water. The Finish Warranty is VOID if (c) the practices specified by 

AAMA 609 & 610-02 – “Cleaning and Maintenance for Architecturally Finished Aluminum” (www.aamanet.org) are not followed by 

Purchaser for IronRidge’s aluminum based components; and (d) if the practices specified by ASTM A780 / A780M - 09 “Standard Practice 

for Repair of Damaged and Uncoated Areas of HotDip Galvanized Coatings” are not followed by Purchaser for IronRidge’s galvanized 

steel-based components.

The warranties above do not cover any parts or materials not manufactured by IronRidge, and exclude nonfunctionally-related defects, 

as defined solely by IronRidge.  The warranties do not cover any defect that has not been reported to IronRidge in writing within 

twenty (20) days after discovery of such defect. 

In the event of breach of or non-compliance with the warranties set forth above, IronRidge’s sole obligation and liability, and the sole 

and exclusive remedy for such breach or non-compliance, shall be correction of 

defects by repair, replacement, or credit, at IronRidge’s sole discretion. Such repair, replacement or credit shall completely satisfy and 

discharge all of IronRidge’s liability with respect to these warranties.

Refurbished Product may be used to repair or replace the defective components. Transportation, installation, labor, or any other costs 

associated with Product replacement are not covered by these warranties and are not reimbursable. These warranties additionally 

do not cover (a) normal wear, or damage resulting from misuse, overloading, abuse, improper installation (including failure to follow 

professional instruction and certification), negligence, or accident, or from force majeure acts including any natural disasters, war or 

criminal acts; and (b) Products that have been altered, modified or repaired without written authorization from IronRidge or its 

authorized representative; and (c) Products used in a manner or for a purpose other than that specified by IronRidge. A formal 

document proving the purchase and the purchase date of the Product is required with any warranty claim.

Except as set forth above, IronRidge sells the Products on an “AS IS” basis, which may not be free of errors or defects, and ALL EXPRESS 

OR IMPLIED REPRESENTATIONS AND WARRANTIES, INCLUDING ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR 

PURPOSE, QUALITY, WORKMANLIKE EFFORT, CORRESPONDENCE TO DESCRIPTION, DESIGN, TITLE OR NON-INFRINGEMENT, OR ARISING 

FROM COURSE OF DEALING, COURSE OF PERFORMANCE OR TRADE PRACTICE, ARE HEREBY DISCLAIMED.

Summary of Contents for Light

Page 1: ...Installation Manual 2013 Edition v1 13 A complete manual for the installation of IronRidge s rail systems with integrated grounding Standard XRS and Light XRL Rails with Integrated Grounding Conforms to UL SUB 2703 4008083 ...

Page 2: ...he IronRidge Standard XRS and Light XRL Rail Mounting Systems with Integrated Grounding Customer Support Tools Required For Assembly Torque Values Component List Assembly Steps 1 3 4 Assembly Steps 3 4 5 Assembly Steps 4 5 6 Assembly Step 5 6 7 Warranty Information 9 TOC ironridge com 800 227 9523 2013 v1 13 support Module Clamp Table 2 Rails with Integrated Grounding Installation Manual 8 ...

Page 3: ...ing devices including lag screws have adequate pullout strength and shear capacities as installed VI Maintaining the waterproof integrity of the structural support or roof including selection of appropriate flashing VII Ensuring safe installation of all electrical aspects of the PV array VIII Ensuring that PV module is installed per module manufacturer s installation requirements the PV module man...

Page 4: ... Use the following torque values in this assembly Module Clamp Table Millimeters Inches End Clamp Grounding Mid Clamp 31 0 32 5 1 22 1 28 29 7000 125 RS GD MCL 200 33 3 34 8 1 31 1 37 29 7000 134 RS GD MCL 200 34 8 36 8 1 37 1 45 29 7000 224 RS GD MCL 225 39 0 41 0 1 53 1 61 29 7000 157 RS GD MCL 225 41 1 42 7 1 62 1 68 29 7000 165 RS GD MCL 250 42 7 44 2 1 68 1 74 29 7000 171 RS GD MCL 250 45 0 4...

Page 5: ...aches to L foot and provides support for the PV modules Grounding Mid Clamp Secures PV modules to rails and provides grounding to the rail and between the two adjacent modules Internal Splice Provides a structural connection when connecting rails End Clamp Secures PV modules to rails utilizing the rail top slot End Cap Caps off the end of the rail and prevents the collection of debris inside rail ...

Page 6: ...onnection Note Attaching rails to L Feet may be performed before or after making rail to rail connections depending on the installer s preference Note This connection requires proper grounding on rails with grounding lugs by using one of the two following Rail to Rail Connection methods For rails without lugs use the Internal Splice and self drilling screws without the grounding strap and star was...

Page 7: ...p 1 4 T Bolt Step 4 Equipment Grounding Note In order to properly ground the PV modules and IronRidge components to the equipment ground a grounding lug or Lay in Lug must be attached to one 1 rail near the end of each row This connection requires the use of one of the two following lugs IronRidge Grounding Lug 1 Using a 13 64 or 7 drill bit drill a hole through one side of the Standard Rail both ...

Page 8: ... copper grounding conducting wire 1 4 Hex Nut Torque to 10 ft lbs 1 4 Lock Washer 1 4 Flat Washer 1 4 Hex Bolt Torque to 7 ft lbs Weeb 1 4 Hex Bolt Step 5 Installing Modules End Clamp A Place the first PV module in position on the rails Module should be a minimum of 1 5 from end of rail B Next secure End Clamp on rail as shown Ensure End Clamp is securely hooked over top of module C Repeat with en...

Page 9: ...ding Mid Clamp and secure with hardware Ensure the Grounding Mid Clamp teeth are in contact with both of the PV module frames and the T Bolt is properly aligned in track T Bolt indent should be perpendicular to rail F Repeat steps for other clamp and modules End Clamp G Secure the last PV Module with an End Clamp repeating steps above 1 4 Hex Nut Grounding Mid Clamp 1 4 T Bolt Torque to 84 in lbs ...

Page 10: ...mply with all national state and local installation procedures product and safety standards These standards include but are not limited to applicable National Electrical Code NEC sections National Electrical Installation Standards NEIS UL Standards and OSHA Regulations Basic Grounding Diagram A IronRidge Grounding Lugs and Wiley Electronics LLC WEEB 6 7 are approved for use with this system B The ...

Page 11: ...owed by Purchaser for IronRidge s galvanized steel based components The warranties above do not cover any parts or materials not manufactured by IronRidge and exclude nonfunctionally related defects as defined solely by IronRidge The warranties do not cover any defect that has not been reported to IronRidge in writing within twenty 20 days after discovery of such defect In the event of breach of o...