Innovative Hearth Products

IronStrike™ Brand Gas Fireplaces, Stoves and Inserts

20 Year Limited Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your IronStrike™ brand gas fireplace or insert ("Product") to be free from defects in materials and 

workmanship at the time of manufacture. The Product body and firebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal 

breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 Year Limited Warranty 

period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or replacement is not 

commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also pay IHP prevailing labor 

rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS AND LIMITATIONS to this 20 

Year Limited Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of installation. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the 

date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed instruc-

tions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 

provided. The Product body and firebox carry the 20 Year Limited Warranty from the date of installation. Vent components, trim components and paint are excluded from this 

20 Year Limited Warranty. The following do not carry the 20 Year Limited Warranty but are warranted as follows:

Burner 

– Repair or replacement for one year from the date of installation

Gas components

 – Repair or replacement for one year from the date of installation

Gaskets

 – Repair or replacement for one year from the date of installation

Gold & nickel plating

 – Replacement for two years from date of installation. Excludes tarnishing

Logs

 – Replacement for one year from the date of installation against thermal breakage only

Optional blowers & remote controls

 – Repair or replacement for one year from the date of installation

Optional glass doors

 – Repair or replacement for 90 days from the date of installation

Tempered glass

 – Replacement for one year from the date of installation

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component

Parts not otherwise listed carry a 90 day warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either 

natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures and 

could result in a fire hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; (d) 

damages, repairs or inefficiency resulting from faulty installation or application of the Product.

IHP is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction conditions 

which may generate negative pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for drafting conditions caused by venting 

configurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit.

This 20 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction, which are not 

manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to 

any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, or 

in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after 

repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a particular 

use or purpose, and there is no implied condition of fitness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.

No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 

do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 20 Year 

Limited Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefits and advantages described in this 20 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. 

IHP shall in no event be responsible for any warranty work done by a contractor 

that is not approved without first obtaining IHP's prior written consent.

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP 

Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.IRONSTRIKE.US.COM.

Printed in U.S.A. © 2013  Innovative Hearth Products LLC

P/N 900197-00, Rev. NC  12/2013

Innovative Hearth Products

1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210

Summary of Contents for Madison Park MPI27

Page 1: ...If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage AVERTISSEMENT RISQUED INDENDIE OU D EXPLOSION Le non respect Des avertissements de sécurité pour rait ...

Page 2: ...ALIENTE CAUSARÁ QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NIÑOS DEBEN NUNCA TOCAR EL VIDRIO L écran pare étincelles fourni avec ce foyer réduit le risque de brûlure en cas de contact accidentel avec la vitre chaude et doit être installé pour la protection Des enfants et Des personnes à risques incluse avec le façade Requis Unabarrera diseñadaparareducirelriesgodequemadurasdesdelamir...

Page 3: ... en funcionamiento Supervise en forma cercana a los niños en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio Mantenga la ropa mobiliario gasolina y otros líquidos inflamables alejados de la chimenea Aún después de haber apagado el gas las superficies de la chimenea permanecen extremadamente calientes Asegúrese de colocar las Etiquetas de advertencia de s...

Page 4: ...List 12 Ratings 12 Insert and Fireplace Dimensions 13 Clearances to Combustibles 14 Insert Leveling 14 Installation 15 20 USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual Please pay special attention to the safety instructions provided in this manual PRODUCT IS SUBJECT TO CHANGE WITHOUT NOTICE Venting Installation 15 Preparation For Flex Liner Install...

Page 5: ...ls viennent en contact avec la surface chaude Il est recommandé d installer une barrière physique si des personnes à risques habitent la maison Pour empêcher l accès à un foyer ou à un poêle installez une barrière de sécurité cette mesure empêchera les tout petits les jeunes enfants et toute autre personne à risque d avoir accès à la pièce et aux surfaces chaudes 7 Tout écran ou protecteur retiré ...

Page 6: ...ra quitarelpolvoyaceite Peguelaetiquetaadyacente alinterruptordecontroldelquemadorquecontrola elartefacto FiguraA Seleccioneelidiomaquemás se habla en la casa 2 Identifique el transmisor de control remoto y límpielo bien para quitar el polvo y aceite Pegue la etiqueta en la superficie del transmisor Figura B Seleccione el idioma que más se habla en la casa 3 Si no puede encontrar las etiquetas sír...

Page 7: ... étiquettesurleboîtier de la télécommande Figure B Choisissez la langue qui est principalement parlée dans la résidence du propriétaire En cas de doute collez l étiquette en anglais 3 Sivousneparvenezpasàlocaliserlesétiquettes s il vous plaît contactez IHP ou votre revendeur le plus proche pour recevoir IHP étiquettes d instructions de sécurité supplémentaires gratuitement Étiquettes de remplaceme...

Page 8: ...with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes Turn off gas and electrical power to the appliance and allow it to cool before cleaning or servicing the appliance If the barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier for this appliance Si l écran est endommagé il doit être remplacé par celui fournit par le...

Page 9: ...er use solid fuels such as wood paper cardboard coal or any flammable liquids etc in this appliance Plated surfaces must be cleaned with glass cleaner and a clean soft cloth before firing the first time or fingerprints will remain permanently NEVER use brass polish to clean plated surfaces this will remove the plating CAUTION Hot while in operation Do not touch Severe Burns mayresult Keepchildren ...

Page 10: ...ed for use with either natural gas or propane Is NOT for use with solid fuels Is approved for sitting rooms and or bedrooms This appliance is suitable for installation into masonry or factory built fireplaces Fireplace Requirements These heaters are designed to be installed into an existing masonry fireplace built to UBC 37 or ULC S628 standards or factory built solid fuel wood burning fireplace l...

Page 11: ...be tested and certified by a nationally recognized testing and certification laboratory to ANSI American National Standard Institute gas appliance safety standards This appliance has been tested and certified to ANSI Z21 88 CSA 2 33 Standard for Vented Gas Fireplace Heater and CAN CGA 2 17 M91 and UL 307B Gas Burning Heating Appliances for Manufactured Mobile Homes in both USA and Canada This appl...

Page 12: ... details PRE INSTALLATION RATINGS MPI27 and MPI27CD NATURAL GAS LP GAS Max Min Input BTUh 0 2 000 Feet 0 610 M u 30 000 21 000 25 000 20 000 Manifold Pressure IN WC 3 5 10 0 Min Inlet Pressure IN WC 5 0 10 5 AFUE Efficiency MPI27 67 MPI27CD 67 MPI27 70 MPI27CD 69 P4 Efficiency v MPI27 68 MPI27CD 66 MPI27 71 MPI27CD 68 Orifice DMS 0 2 000 Feet 0 610 M u 38 53 uUnit factory equipped for 0 2000 FT 0 ...

Page 13: ...D Figure 3 Minimum Fireplace Cavity Figure 2 Insert Dimensions 26 5 8 676mm 16 3 4 425mm 8 3 4 222mm 10 7 8 276mm 14 7 8 378mm 17 7 8 454mm 14 3 8 365mm 20 3 4 527mm O D 2 15 16 75mm Minimum Fireplace Opening A 27 686mm Front Opening Width B 18 457mm Height C 17 432mm Rear Width D 15 381mm Fireplace Depth ...

Page 14: ...tandoffsorsurfacestocombustibleconstruction etc above the appliance Paint or lacquer used to finish the mantel must be heat resistant in order to avoid discoloration Facing and Mantel Clearances see Figure 4 The letters in Figure 4 A through E show minimum clearances required from the appliance to combustibles and the minimum projection of the hearth extension Figure 4 Clearances Insert Leveling A...

Page 15: ...ing and Termination Cap 46DVA CL33 Preparation For Flex Liner Installation The liner connector plate can be removed as shown in Figure 6 to make it easier to connect the flex liners to the intake and exhaust collars Re install the liner connector plate when the insert is placed in the fireplace NOTE Ensuregasketonconnectorplateisnotdamagedbeforere installing INSTALLATION Figure 6 Intake Liner Conn...

Page 16: ... not operate When done assure all connections are securely fastened NOTE Theminimumverticalrise exhaustvent is10feet 3 1M andthe maximum vertical rise is 25 feet 7 6 M These dimensions are measured from the base of the unit to the end of the vent pipe The fireplace and fireplace chimney must be clean and in good working order and constructed of non combustible materials Inspect chimney cleanouts f...

Page 17: ...amenée du gaz un orifice d au plus 38 1 mm 1 5 po peut être pratiqué selon les règles de l art dans la partie inférieure des parois ou au fond de la chambre de combustion Cet orifice doit être obturé au moyen d isolant incombustible une fois la conduite de gaz en place The installer must mechanically attach the marking supplied with the gas fireplace insert to the inside of the firebox of the fire...

Page 18: ...3 Figure 14 4 Place a layer of glowing embers rockwool directly over the ports Figure 11 A light layer will give a more constant rear flame A heavy layer will give more glow but may need to be adjusted after light up to prevent sooting and poor flame quality 5 Place volcanic stones around the perimeter of the glowing embers rockwool in the areas shown in Figure 12 IMPORTANT Do not cover ports with...

Page 19: ... supplied with this manual Figure 16 Surround Mounting Tab Surround Mounting Tab Facade Mounting Tab Figure 15 Firebox Media Installation Optional kit See Page 35 for ordering information 1 Measure out approximately 3 cups of glass media and place an even layer on burner as shown in Figure 15 Care should be taken to NOT block pilot opening in burner tray or mound up media 2 Remove reflective accen...

Page 20: ...ting insert a small flat blade screwdriver into the tap and turn a half turn counter clockwise Cover the tap with the line from the manometer and check the pressure Again close the tap gently but securely after completing the check Check the taps for gas leaks with a gas leak test solution retighten if necessary If the pressure is not sufficient make sure the gas supply line is large enough the su...

Page 21: ...ust the air shutter slide the adjustment lever side to side see Figure 18 CAUTION The air shutter should never be set so as to make the tips of the flames sooty or create sooting on the viewing glass logs or heat exchanger If soot begins to form after burning the air shutter should be opened gradually until the sooting condition stops Gas quality and gas pressure may vary which can affect the burn...

Page 22: ...tric power to the appliance if service is to be performed 3 Close the main line gas shut off valve WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand B BEFORE OPERATING smell all a...

Page 23: ...standing pilot simply by using the remote to switch from IPI to CPI This is done when the remote is in the off position Press the mode key and use the up down arrow key to change between IPI and CPI To save energy switch to intermittent mode To have a standing pilot which will help startup during cold climate conditions by warming the flue and the glass switch to standing pilot The standing pilot ...

Page 24: ...ystem or activating manual bypass of the remote system CAUTION Propertydamagehazard Excessiveheatcancause propertydamage Theappliancecanstaylitformany hours Turn off the appliance if it is not going to be attended for any length of time Always place the Transmitter where children can not reach it Figure 22 Remote transmitter Figure 21 ON OFF Key THERMOSTAT Key UP DOWN Arrow Key MODE Key Blue LCD D...

Page 25: ...s turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position see Figure 25 A single beep will confirm reception of the command Room Thermostat Remote Operation The Remote Control can operate as a room thermostat The thermostat can be set to a desired temper...

Page 26: ... heat up and the flames will become a yellow orange color Adjusting the appliance to cause the flames to turn orange sooner may result in poor combustion sooting and a hazardous situation See Figure 26 showing proper flame appearance When testing for proper operation If an optional thermostat is installed adjust it to its highest temperature setting Visually determine that main burner gas is burni...

Page 27: ... commandes étiquetez tous les fils avant de les débrancher Des erreurs de cáblage peuvent entraîner un fonctionnement inadéquat et dangereux VALVE BURNER PILOT ON OFF SWITCH PILOT ROOM AIR BLOWER BATTERY HOLDER ACCENT LIGHT POWER CORD GRN YLW BLK BRN YLW ORG ORG RED BLK WHT BLK WHT GRN GRN YLW ORG WHT GRN WHT BLU BLU BLK 1 4 PRG BUTTON X6 X5 X4 X3 X2 X1 X10 X11 FEMALE DISCONNECT MALE DISCONNECT ST...

Page 28: ...an those approved for use with this appliance o Check that the chimney and its outlet are open and free of soot block age or debris The venting system should be periodically examined by a qualified agency o Check gaskets once a year Gaskets must be tight Replace if neces sary o Periodically inspect the pilot system for proper flame Turn the pilot ON Auto switch to the ON position Ensure the ignite...

Page 29: ...on these doors or replace cracked or broken glass Handle this glass with extreme care Glass is susceptibletodamage Donotscratchorhandle roughly while reinstalling the glass door frame The glass door s of this appliance must only be replaced as a complete unit as provided by the manufacturer Donotattempttoreplacebroken cracked or chipped glass separately Do not attempt to touch the front enclosure ...

Page 30: ...lectrical Code Part 1 CSA C22 1 latest edition See Operating Options for burner ON OFF switch information Figure 31 Blower Assembly Removal Blower Assembly Fireplace Insert Back Repair If the glass is broken in the glass door the entire door metal frame gasket and glass should be replaced as a unit This replacement glass door is available from your IHP dealer Do not use substitute parts or materia...

Page 31: ...emporary and Santa Fe Facades a Using a 3 8 nut driver remove and set aside the four nuts and Z brackets holding each corner of the barrier in place b Remove the damaged barrier from the facade and discard Deco Facades a Using a 3 8 nut driver remove and set aside the two nuts and Z brackets holding the top corners of the barrier in place b Using a flat blade screwdriver careful pry up the two tab...

Page 32: ...on on Page 17 through 20 The main Burner comes on but then goes out Gas is not reaching the appliance Loose wires to the valve or ignition module Pilot flame is not engulf ing the sensor Obstructed vent system Check the gas supply and gas shutoff valves Checkcontrolcompartmentforanyobviousloosewiring callaservicetechnicianifrequired Call for a service technician Call for a service technician Nothi...

Page 33: ...rd Thermal Barrier Kit 14 H9178 Façade Mounting Bracket Kit set of two 15 H9183 Refractory Panel Retaining Bracket Kit two sets one of each style 16 H9181 Media Burner Support Tray Kit MPI27CD only 17 H9170 Media Burner Assembly includes shutter assy MPI27CD only 18 H9182 Media Burner Accent Glass MPI27CD only 19 H9180 Log Support Panel Kit MPI27 only 20 H9169 Log Burner Assembly MPI27 only 21 H91...

Page 34: ...34 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS MPI27 MPI27CD 1 2b 4 5 6 7 8 9 10 11 12 13 14 15 16 3a 3b 17 20 19 21 22 23 2a 18 24 25a 25b 26 3A 3B 3b 3a ...

Page 35: ... MPI27 Madison Park 27 Small Insert 87 5 lb 12 22 cu ft H9123 MPI27CD Madison Park Contemp 27 Small Insert 80 lb 12 22 cu ft Surround Kits required accessory Cat No Model Description H9131 FP2637 MPDVI27 3 Sided Surround 37 W x 26 H H9132 FP2641 MPDVI27 3 Sided Surround 41 W x 26 H H9133 FP3037 MPDVI27 3 Sided Surround 37 W x 30 H H9134 FP3041 MPDVI27 3 Sided Surround 41 W x 30 H H9135 FP3846 4S M...

Page 36: ...38mm Du bas de l appareil au dessous de la finition supérieure 32 813mm B Mur de côté 9 1 2 241mm C 6 152mm manteau de foyer à partir de la base 34 864mm PROTECTION DU FOYER D Distanceverticaledelabasede 0 4 del appareilàl extensiond âtre 0mm 102mm E Extensiond âtremin àl avant 10 0 del appareil 254mm 0mm Voir le manuel d entretien pour les informatinos supplémentaires reliées aux distances à resp...

Page 37: ...SI NFPA 54 DERNIÈRE ÉDITION ETATS UNIS OU CAN CGA B149 1 DERNIÈRE ÉDITION CANADA CET APPAREIL DOIT ÊTRE INSTALLÉ SELON LES DIRECTIVES D INSTALLATION DU FABRICANT POUR INSTALLATION DANS DES FOYERS À COMBUSTIBLE SOLIDE SEULEMENT DE MAÇONNERIE OU PRÉFABRIQUÉ EN USINE CE FOYER RADIANT AU GAZ À ÉVACUATION N EST PAS CONÇU POUR ÊTRE UTILISÉ AVEC DES FILTRES À AIR CET APPAREIL DOIT ÊTRE UTILISÉ AVEC LE TY...

Page 38: ...entraînant des dommages des blessures ou la mort A Cet appareil est muni d un dispositif d allumage qui allume automatiquement la veilleuse Ne tentez pas d allumer la veilleuse manuellement B AVANT DE FAIRE FONCTIONNER reniflez tout autour de l appareil pour déceler une odeur de gaz Reniflez près du plancher car certains gaz sont plus lourds que l air et peuvent s accumuler au niveau du sol QUE FA...

Page 39: ...mage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages repairs or inefficiency resulting from faulty installation or application of the Product IHP is not responsible for inadequate fireplace system draft caused by air cond...

Page 40: ... your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions conce...