background image

ENGLISH

Page 7

for iRoom‘s fixDock

MANUAL

Installation in Cavity Walls

1. 

Attach the aluminum frame (2) to the back box (3) and bolt 
together the frame and the back box with the included mounting 
screws (1) (3 x 20mm)

2.  Prepare a recess in the wall. You will find the cut-out dimensions 

for your fixDock model on page 6.

3.  Remove the break-out for the cable exits on the back box
4.  Feed in the power leads through the hole in the back box . Use a 

suitable cable grip sleeve.

5.  Place the back box in the recess. Do not deform the

back box.

6.  Cut some small thread gaps in the safety strips that cover the 

recess spaces for the mounting clips.  Do not remove the safety 
strips! Feed the mounting clips into the recesses and screw 
them tight. Ensure a straight, flush wall and distortion-free 
installation of the flush box. Otherwise it may cause mechanical 
problems.

Mounting

1. 

Connect the original Apple charging cable to the USB port of the 
included 110-240 VAC to 36 VDC power supply.

2.  Connect the iPad to charging cable. If you install an iPad with 

USB-C charging port use the included USB-A to USB-C adapter.

3.  Fix the iPad to the backside of the glass bezel using the included 

rubber bands - see below. Pay attention to correct positioning of 
the rubber band clips.

4.  Push the fixDock into the aluminium frame. Make sure you do 

not damage the power leads. 
Ensure a proper locking of the magnetic mounting system.

5.  Switch on main power supply.
6.  To remove the dock from the aluminium frame use the included 

sucker.

Rubber Band Clips

Summary of Contents for fixDock mini

Page 1: ...MANUAL fixDock mini iPad10 11 12 9 English Deutsch intelligence on iRoom fixDock 2020 Lineart iRoom fixDock with device iRoom fixDock without device...

Page 2: ...ply High or Low voltage 1x Adapter USB A to USB C 1x only fincluded with fixDock models for iPads with a USB C charging port Introduction Thank you for purchasing iRoom s fixDock in wall docking stati...

Page 3: ...onments The place chosen to mount the device must provide enough recess depth to allow use of the back box and the entry of the leads Mount the device in a place that enables reception of a suitably s...

Page 4: ...Preparing the Power Connection Option 1 High Voltage Connect the AC USB converter to a 110 240 VAC power line and put it in the back box of the docking station This option requires a certified electr...

Page 5: ...primary power adapter 110 240 VAC to 36 VDC into a power outlet 2 If needed run a 2 wire extension cable not included from the 36VDC output to the next converter 3 Put the second converter included i...

Page 6: ...the break out for the cable exits on the back box 4 Feed in the power leads through the hole in the back box Use a suitable cable grip sleeve 5 Place the back box in the recess Do not deform the back...

Page 7: ...trips Feed the mounting clips into the recesses and screw them tight Ensure a straight flush wall and distortion free installation of the flush box Otherwise it may cause mechanical problems Mounting...

Page 8: ...mm x 295mm x 83mm 14 2 x 11 6 x 3 3 Function Description Store charge the iPad Low Voltage Power Supply Primary 100 240VAC to 36 VDC 1A Secondary 8 52 VDC to USB 5VDC 2A High Voltage Power Supply Powe...

Page 9: ...uthorized and or forceful removal of the iPad cannot be prevented iRoom GmbH does not accept any liability for the theft of an iPad Limited Warranty iRoom GmbH warrants that the product s furnished he...

Page 10: ...and or altered or an addition made thereto except by iRoom GmbH or iRoom GmbH authorized representatives or as approved by iRoom GmbH in writing 2 has been painted rebranded or physically modified in...

Page 11: ...sed of within the European Union this product should be treated and recycled in accordance with the laws of your jurisdiction implementing the WEEE Directive Declaration of Conformity Hereby iRoom Gmb...

Page 12: ......

Page 13: ...Schwachstrom 1x Adapter USB A auf USB C 1x nur bei fixDock Modellen f r iPads mit USB C Ladestecker Einleitung Danke dass Sie sich f r unsere Wandeinbau Dockingstation fixDock von iRoom entschieden ha...

Page 14: ...nassen oder feuchten Umgebungen Der Installationsplatz muss gen gend Wandtiefe bieten um die Montage der Unterputzdose zu erm glichen Montieren Sie das Ger t an einem Ort der ein entsprechend starkes...

Page 15: ...en des Stromanschlusses Option 1 Starkstrom Verbinden Sie den AC USB Konverter mit einem 240 VAC Anschluss und platzieren Sie diesen in der Unterputzdose der Dockingstation Diese Art der Installation...

Page 16: ...40VAC auf 36 VDC in eine 240 Volt Steckdose 2 Falls erforderlich verl ngern Sie das 36 VDC Kabel mit einer 2 Draht Leitung nicht enthalten zum n chsten Konverter 3 Legen Sie den beigelegten zweiten Ko...

Page 17: ...Modell auf Seite 16 finden 3 Enfernen Sie den Ausbruch f r die Kabelausg nge in der Unter putzdose 4 F hren Sie die Kabel durch den W rgenippel der Unterputzdose 5 Setzen Sie die Unterputzdose in die...

Page 18: ...ie Befestigungsklammern in die Aussparungen und schrauben Sie diese fest Vergewissern Sie sich dass die Unterputzdose eben fl chenb ndig und glatt in der Wand sitzt Andernfalls kann es zu Montageprobl...

Page 19: ...x 11 6 x 3 3 Funktionsbeschreibung Aufbewahren und Laden des iPads Schwachstrom Netzteil Prim res Netzteil 100 240VAC to 36 VDC 1A Sekund res Netzteil 8 52 VDC to USB 5VDC 2A Starkstrom Netzteil Netzt...

Page 20: ...indert werden Im Fall des Diebstahls eines iPads bernimmt die iRoom GmbH keinerlei Haftung Eingeschr nkte Gew hrleistung Die iRoom GmbH garantiert dass das die Produkt e die im Rahmen dieses Vertrages...

Page 21: ...rde 2 bemalt umbenannt oder in der Form ver ndert wurde 3 infolge von Fehlern und Defekten der Verdrahtung besch digt wurde 4 wenn es einem falschen Gebrauch Missbrauch Unachtsamkeit unsachgem er phys...

Page 22: ......

Page 23: ......

Page 24: ...hen wurde in bereinstimmung mit der EU Richtlinie 2011 65 EU ber Elektro und Elektronikger te Abfall die WEEE Richtlinie angebracht Wenn das Produkt innerhalb der Europ ischen Union entsorgt wird muss...

Reviews: