EN
59
Table 1
N°
Default value & other possibilities
00 RF INI:
Radio configuration
Sends the radio link signal in order to assign this RF Thermostat with its RF receiver.
You also need to set simultaneously the receiver in radio configuration mode (On a simple receiver press and maintain button until
the green light lits up, see the receiver leaflet)
01 FP
: Pilot wire connection used in the receiver
Yes/no
02 OPEN:
Open Window Detection
Yes/no
The Open Window Detection detects an "Opened window" if the displayed temperature (internal or ambient sensor) decreases by
1,2°C or more in less than 10 minutes.
In this case, the thermostat stops heating and regulation setpoint switches to antifreeze.
As an indicator of this function, the room temperature and a hand will blink.
Return to normal mode:
The thermostat returns automatically to normal mode when temperature rises of 0.3°C in less than 10 minutes
The function can be overridden by pressing the (OK) button during the stop heating phase.
Then the blinking temperature should stop to indicate the end of the detection.
Special cases:
- This function doesn't work if Thermostat is in OFF / Antifreeze Mode
- If temperature is less than 10°C, thermostat will regulates at 10°C during the stop phase
03 ItCS:
Intelligent Temperature Control System
Yes/no
The Intelligent Temperature Control System will activate your installation in advance (2 hours maximum) to assure the desired
temperature at the hour programmed following your weekly program. This automatic control system works in the following way:
When you start your thermostat for the first time, it will measure the time taken by your installation to reach the set temperature.
The thermostat will re-measure this time at each program change to compensate external temperature change & influence. You
can now program your thermostat without the need to adjust the temperature in advance because your thermostat does it
automatically for you.
04 dEGr
: Unit of the temperatures displayed
°C:
Celsius
°F:
Fahrenheit
05 __:__
Selection of the Time clock format
24H
(24:00)
12H
(12:00 AM /PM)
06 dst:
Daylight Summer time change Summer<->Winter
YES:
automatic change according to date.
No:
no daylight summer time automatic change.
07 HG
: Anti-freeze temperature used in Holiday mode
Default value 10°C.
Use the (-) or (+) keys to change the anti-freeze setting temperature from 0,5 to 10°C. Then press (Ok) to confirm.
08 AirC:
calibration of internal sensor
no:
no offset is applied on the sensor.
YES:
an offset is applied
Press buttons “-“ or ”+” to adjust temperature sensor offset.
Press buttons “-“ and ”+” together to suppress offset and come back to factory setting.
Important Note: this features could be available only when remote control is paired with some kind of receiver.
09
Software version
VErS
___
10 Clr ALL
: Reset to Factory setting
Press and maintain (Ok) key during 10s to reset set points temperatures and user parameters in this menu to factory default
settings. User programs will also be resetted.
Pay attention:
Ensure you that you have all necessary elements to re-setup your installation before using this function.
11 End
: Exit the parameter’s menu
Press (OK) key to exit installation parameter menu and return to normal operation.