TECHNICAL
MANUAL Drive 2000 Mini Evo
October 2016-Rev. 1
9
3.3
Power data
Drive
type
Rated rms
current
Rated pk.
current
Max. rms
current
Max. peak
current
Rated
power
Max.
power
(I
rms rated
)
(I
peak rated
)
(I
rms max
)
(I
peak max
)
(P
rated
)
(P
max
)
(A)
(A)
(A)
(A)
(kW)
(kW)
Mini
2004
4
5.7
8
11.3
1.5
3
Note:
Irms = Ipeak / 1,41
Vrms = 220V or 390V
P = 1,73 x Irms x Vrms
or
P = 3 x Irms/phase x Vrms/phase
Braking power :
Drive
type
R
braking
Peak braking
power
Max. continuous
braking power
Surge energy
(
T=300K)
(
)
(W)
(W)
(J)
Mini
2004
100
1500
100
The surge energy rating is the maximum permitted dynamic brake application from cold. To
a first approximation, heat is then removed at the rate given by the continuous power
figure, thus about 20 seconds interval must be allowed between full energy stops.