34
2019-08
USE AND MAINTENANCE MANUAL
METRO’ MY19
EN
428001167037
15.1
USER INTERFACE
°C
°F
FUNCTIONS
TEMPERATURE
MINIMUM
1.
Press and release the key; the message "Lo" will be displayed followed by the minimum
temperature reached.
2. Press the key or wait 5 seconds to display the normal temperature again.
MAXIMUM
1.
Press and release the key; the message "Hi" will be displayed followed by the maximum
temperature reached.
2. Press the key or wait 5 seconds to display the normal temperature again.
CANCELLATION
1. When the saved temperature is viewed, hold the SET button pressed for a few seconds
(the letters rSt appear).
2.
To confirm, the letters rSt will begin to flash.
SET-POINT
DISPLAY
1.
Press and release the key; the set-point will immediately be displayed.
2. To view the temperature again wait 5 seconds, then press the key again.
CHANGE
Press the key for at least 2 seconds; the set-point will be displayed and the LED
°C
starts
to flash.
To change the value use the
DOWN
/
UP
keys.
To save the new set-point press the
SET
key or wait 15 seconds to exit the programming func-
tion.
KEYBOARD
LOCK
Hold the keys pressed for a few seconds until the letters “POF” start to flash: the keyboard is
locked (only the set-point and minimum and maximum temperature can be viewed).
UNLOCK
Hold the keys pressed for a few seconds until the letters “POn” start to flash: the keyboard is
unlocked.