background image

EMERGENCY STOP 

The switching-off of the machine can be performed 

by pressing the “ON-OFF” switch on pos. “OFF 

(0)”. In order to avoid situations of imminent or 

close hazard, the authorized operators must 

compulsorily perform the following operations:

1. 

Press the “on-off” switch On pos. “Off (0)” in the right time.

2. 

Immediately inform the “safety manager” of the emergency (if 

the machine is used in a company).

1. 

Switch off the machine by pressing the “ON-OFF” switch on 

pos. “OFF (0)”;

2. 

Disconnect the machine from the mains by removing the 

power supply plug from the proper outlet;

3. Disconnect the tool from the air tube (extension);

4. Disconnect the air tube (extension) from the fast air outlet tap 

of the machine;

5. Drain the condensate from the tank only in case of work cycle 

end.

RESTORABLE THERMAL PROTECTION TRIPPING 
RESET

Should a current overload and/or short-circuit 

occur in the electric plant of the machine, 

the restorable thermal switch trips stopping 

the electric motor. To reset the restorable 

thermal switch, proceed as follows;

1. 

Press the “ON-OFF” switch on pos. “OFF (0)”;

2. 

Press the restorable thermal push-button;

3. Before restarting the machine wait some minutes.

bar

0

Should the machine, after having performed the rest, not 

switch on, the charged operator must compulsory seek 

the intervention of the maintenance technical engineers 

and/or of the authorized dealer.

MACHINE SWITCHING OFF

At the end of the work cycle, switch 

off the machine as follows:

bar

0

CONNECTIONS

The machine can be connected to the mains 

by  inserting  the  power  supply  plug  in  the 

proper outlet.

ELECTRICAL CONNECTIONS

The mains to which the machine is connected 

must comply with the requirements foreseen by the 

regulation in force in the country of use, as well as 

meet the technical features quoted in par.2 And be 

equipped with a proper “earthing” plant.

Any type of electric material used for the connection 

must suit the use, be marked “ce” if subjected to the 

low voltage directive 2006/95/ec, and comply with the 

requirements set forth by the regulations in force in 

the country of use of the machine.

The inobservance of the above described warnings 

can cause irreparable damages to the electric 

equipment of the machine and the following 

expiration of the warranty.

The manufacturers declines all liability for fauilts or 

malfunctions of the machine due to voltage sudden 

bar

0

changes exceeding the tolerances foreseen by the 

distributing entity (voltage ± 10% - frequency ± 2%).

Should it be necessary, it is compulsory to connect 

the machine exclusively to generating sets with a 

power greater than the installed electric power. To 

support the absorption peak at start.

It is strictly forbidden to use air tubes (extensions), 

fittings, and tools not suitable and/or not complying with 

the regulations in force.

It is compulsory to use air tubes (extensions), fittings, 

and tools, complying with the provisions contained in 

the use and maintenance instructions supplied by the 

related manufacturers.

The anufacturer declines all liability for damages to 

persons, animals and things due to the inobservance of 

the above described warnings.

CONNECTION OF THE AIR TUBE (EXTENSION) 
AND OF THE TOOLS

1.

Connect the tools to the air tube (extension);

2.

Connect the air tube (extension) to the 

fast air outlet tap of the machine.

SWITCHING ON AFTER AN EMERGENCY STOP 

Only and exclusively after having removed the 

emergency causes and having carefully assessed 

that the same have not caused damaged and/or 

anomalies to the machine, with the consent of the 

“Safety Manager” (In case the machine is used in 

a company), switch on the machine as described.

EMERGENCY STOP

contained in the use and maintenance instructions 

supplied by the related manufacturers.

6. Perform the processing (the machine restarts 

automatically when the operation pressure falls 

under 7 bar);

7. 

Once the processing has ended, switch off the 

machine as described.

7

EN

Summary of Contents for Senco AC19306BL

Page 1: ...else av de Originale Instruksjonene K ytt ohjeet Alkuper isten Ohjeiden K nn s Brugsanvisning Overs ttelse af de Originale Instruktioner Kasutusjuhend Algse juhendi t lge Naudojimo instrukcijos Origin...

Page 2: ...CONNECTIONS 7 Electrical Connections 7 Connection Of The Air Tube Extension And Of The Tools 7 EMERGENCY STOP 7 Emergency Stop 7 Switching On After An Emergency Stop 7 MAINTENANCE 8 State Of Switched...

Page 3: ...nual requiring a specific knowledge of the machine being equipped with the personal protection equipment This manual is integral part of the machine and must be preserved for future reference until di...

Page 4: ...strictly forbidden to replace any safety device or any of their components with not original spare parts It is compulsory to constantly check the correct operation of all safety devices installed on t...

Page 5: ...ing the use it is compulsory to verify that non authorized people do not get close to the machine The authorized operators are not allowed to let the machine unattended during operation and maintenace...

Page 6: ...lectric material used for the connection must suit the use be marked ce if subjected to the low voltage directive 2006 95 ec and comply with the requirements set forth by the regulations in force in t...

Page 7: ...ed dealer MAINTENANCE STATE OF SWITCHED OFF MACHINE Before performing any type of maintenance and or adjustment intervention on the machine it is necessary to compulsorily drain the tank no pressure t...

Page 8: ...ped with two handles and containing No 1 Dry compressor and No 1 Use and maintenance instructions UNPACKING Once the package has been positioned on the floor on an even surface assuring its stability...

Reviews: