Sheet 5 Introduction of indicator mark
39
Indicator
mark
Indicator
light
Description
Reset
The light is on when an object has been detected in the
protective field under the manual reset mode, reset indicator
will flicker one time when window calibration is being carried
out
Normal
The light is on when no object detected in protective field,
OSSD output ON, the controlled machine is allowed to work
Stop
The light is on when object detected in protective field, OSSD
output OFF, the controlled is not allowed to work.
Warning
The light is on when object detected in warning field, ALARM
output ON
Nixie tube
0: Protective/warning field not set or the field input signal fault
1: Current scanning area is protective/warning field 1
2: Current scanning area is protective/warning field 2
3: Current scanning area is protective/warning field 3
4: Current scanning area is protective/warning field 4
5: OSSD output fault
6: Establish communication connection with computer
9: LSPD set successfully
E: EDM monitoring fault
F: LSPD system fault
Window smudginess display, it will be activated when energy
attenuation to 60% caused by window smudginess
When different conditions coexist, different displays will
circulate (interval 1s)