3. Handling 

 

The supply voltages and the CAN interface is connected to the module via a 96-pin connector on the 
rear side of the module. 

The maximum output current and voltage for the channels 0 to 16 are defined through the position of 
the corresponding potentiometer I

max 

 resp. V

max

It is possible to measure the hardware limits, which has been set with reference to the maximum 
possible current resp. voltage at the according 2-pin socket. 100 % I

max 

resp. V

max

 corresponds to  

2,5 V. The output current and voltage  will be limited to the setting value after it exceeds the threshold 
and the corresponding green LED on the front panel is ‘OFF‘. 
At the bottom on the right side of the front panel is the 2-pin LEMO socket for the safety loop. This 
connector is installed in-line with the upper (SL PIN 22) and lower SL contacts (SL PIN 30) on the HV 
connector (see the pin designation on the front panel or in the pin assignment). The safety loop will be 
closed by connection of the load with help of a connection between PIN 22 and 30 on the HV cable 
side of the connector. If the safety loop is active then output voltage on all channels is present only if 
a current of any polarity is flowing in a range of 5 to 20 mA (i.e. safety loop closed). If the safety loop 
is opened during operation then the output voltages on all channels are shut off without ramp and the 
corresponding bit in the ‘Status module’ will be cancelled. After the loop will be closed again the 
channels must be switched ‘ON’ and a new set voltage must be given before it is able to offer an 
output voltage. 
The pins of the loops are potential free, the internal voltage drop is ca. 3 V. Coming from the factory 
the safety loops are not active (the corresponding bit is always set). Removing of an internal jumper 
on the rear side of the unit makes the loops active. 
(s. App. B “Operator’s Manual CAN-Interface”). 

 

Pin assignment 96-pin connector according to DIN 41612: 

 

PIN 

 

PIN 

 

PIN 

 

Data 

a1 

 

b1 

 

c1 

 

    +5V 

a3 

 

b3 

 

c3 

 

 +24V 

a5 

 

b5 

 

c5 

 

 GND 

a11 

 

 

 

 

 

  

@CAN_GND 

 

 

 

b11 

 

 

 

  

@CANL 

 potential free 

 

 

 

 

c11 

 

  

@CANH 

 

a13 

 

 

 

 

 

 RESET 

 

 

b13 

 

 

 

  OFF with ramp (e.g. at power fail) 

a30 

A4 

b30 

A5 

c30 

GND 

   

 

a31 

A2 

b31 

A3 

c31 

GND 

   

 Address 

field 

a32 

A0 

b32 

A1 

c32 

GND 

   

  module address  ( A0 ... A5) 

 

The hardware signal “OFF with ramp” (Pulse High-Low-High, pulse width 

 100 µs) on pin b13 will be 

shut off the output voltage for all channels with a ramp analogue to the Group access “Channel 
ON/

OFF”

. The ramp speed is defined to V

OUTmax

 / 50 s. This is the actually module ramp speed after 

“OFF with ramp”.  
With help of the Group access “Channel 

ON

/OFF

 all channels are switched “ON” again. 

 

With the address field a30/b30 ..... a32/b32 the module address will be coded.  
(see item 4.4, description 11bit-Identifier). 
Connected to GND 

 A(n) = 0 ; contact open 

 A(n) = 1 

Summary of Contents for EBS F 030

Page 1: ... Certificate of calibration Attention It is forbidden to use the unit if the covers have been removed We decline all responsibility for damages and injuries caused by an improper use of the module It is highly recommended to read the manual before any kind of operation Note The information in this manual is subject to change without notice We take no responsibility for any error in the document We...

Page 2: ... 3000 V voltage difference between the channels of one board must be less or equal than 3000 V Ripple and noise f 10 Hz to 100 MHz typ 10 mV max 50 mV under all load conditions Hardware current trip Potentiometer IImaxI for 16 channels Hardware voltage limit Potentiometer IVmaxI for 16 channels Interface CAN interface potential free Data format floating point single precision setting and measureme...

Page 3: ... a current of any polarity is flowing in a range of 5 to 20 mA i e safety loop closed If the safety loop is opened during operation then the output voltages on all channels are shut off without ramp and the corresponding bit in the Status module will be cancelled After the loop will be closed again the channels must be switched ON and a new set voltage must be given before it is able to offer an o...

Page 4: ...v de Phone 49 0 351 26 996 0 Bautzner Landstr 23 http www iseg hv com Fax 49 0 351 26 996 21 D 01454 Radeberg Rossendorf Germany 4 Pin assignment Multipin Redel HV connector 5 C RTN C RTN 8 9 10 15 14 2 1 C RTN 3 4 13 11 7 6 12 0 C RTN SL PIN 22 SL PIN 30 CCG CCG CCG CCG ...

Reviews: