background image

8  Accesories

CAUTION!

CAUTION!

Only use genuine iseg parts like power cables, CAN cables and terminators for stable and safe operation.

ACCESSORY ITEM

ORDER ITEM CODE

REDEL Socket contact, ERA.05.403.ZLL1

Z592263

REDEL SL sockets Contact, EGG.3B.665.ZZM

Z592262

REDEL socket carrier red SLA.H51.LLZG

Z201035

SHV coupler screw for RG58

Z590162

SHV coupler screw for RG58, >5kV

Z592474

Lemo plug 2-pole without collet chuck (SL)

Z592312

1-pin LEMO connector FFA.00.250.CTAC31

Z200793

2-pin LEMO connector, FGG.00.302.CLAD30

Z201466

9  Order guides

CABLE ORDER GUIDE

POWER SUPPLY SIDE

CONNECTOR

CABLE

CODE

CABLE DESCRIPTION

LOAD SIDE

CONNECTOR

ORDER CODE

LLL = length in m

 

(1

R51.44-G

07

HV cable 6kV Kerpen SL-v2YCeHI  37xAWG26/7red R51.44-A

RG44_C07-

LLL_

RA44

R51.46-G

08

HV cable 6kV Kerpen SL-v2YCeHI  56xAWG26/7red R51.46-A

RG46_C07-

LLL_

RA46

SHV

04

HV cable shielded 30kV (HTV-30S-22-2)

open

SHV_C04-

LLL

Notes:

1)

 

Length building examples: 10cm 

 0.1, 2.5m 

 2.5, 12m 

 012, 999m 

 999

Table 8: Guideline for cable ordering

CONFIGURATION ORDER GUIDE

 (item code parts)

ED

48

1

030

P

504

000

02

00

High 
Voltage, 
Distributor

Numbers
of 
channels

Class

V

nom

Polarity

I

nom

 (nA)

Option (hex)

HV-Connector

Customized
Version

1 = normal 
Current 
Measurement
3 = Low Cost 
Current 
Measurement

three significante 
digits • 100V
For Examle:
030 = 3000V

p = positive
n = negative

two significante
 number
of zeros 
For Examle:
305 = 3mA

Sum of the hex 
codes (see Table
3: Technical 
data: Options 
and order 
information
)
For Example:
SLP = 002

02 = SHV
03 = S08
44 and 46 =
Redel Multipin 
(see 7 Connectors
and PIN 
assignments 
)

00 = none

Table 9: Item code parts for different configurations

EDS High Voltage Power Supply series | Last changed on: 17.06.2020 | 

www.iseg-hv.com

18/21

Summary of Contents for EDS LOW COST

Page 1: ... Voltage Module with Common Floating Ground 16 24 48 channel 1kV 3 kV versions Low cost version with reduced current measurement accuracy very low ripple and noise hardware voltage and current limit voltage control and current measurement per channel programmable parameters www iseg hv com ...

Page 2: ...Rights Reserved This document is under copyright of iseg Spezialelektronik GmbH Germany It is forbidden to copy extract parts duplicate for any kind of publication without a written permission of iseg Spezialelektronik GmbH This information has been prepared for assisting operation and maintenance personnel to enable efficient use The information in this manual is subject to change without notice ...

Page 3: ...ty instructions DANGER DANGER Danger indicates a severe injury hazard The non observance of safety instructions marked as Danger will lead to possible injury or death WARNING WARNING Warning indicates an injury hazard The non observance of safety instructions marked as Warning could lead to possible injury or death CAUTION CAUTION Advices marked as Caution describe actions to avoid possible damage...

Page 4: ... on the basis of his technical training his knowledge and experience as well as his knowledge of the relevant regulations General safety instructions Observe the valid regulations for accident prevention and environmental protection Observe the safety regulations of the country in which the product is used Observe the technical data and environmental conditions specified in the product documentati...

Page 5: ... its specified range WARNING WARNING Before connecting or disconnecting HV cables or any operation on the HV output or the application the unit has to be switched off and discharge of residual voltage has to be finished Depending on application residual voltages can be present for long time periods WARNING WARNING Do not operate the unit in wet or damp conditions WARNING WARNING Do not operate the...

Page 6: ...penings is possible CAUTION Caution When controlling with software the high voltage systems make sure that nobody is near the high voltage or can be injured INFORMATION INFORMATION Please check the compatibility with the devices used EDS High Voltage Power Supply series Last changed on 17 06 2020 www iseg hv com 6 21 ...

Page 7: ...nection 11 3 2 Module status 12 3 3 Hardware Limit 12 3 4 Safety Loop 12 3 5 Delayed Trip 13 4 Options 13 4 1 SLA Active safety loop 13 4 2 SLP Internally powered safety loop 13 5 Front panel versions 14 6 Dimensional Drawings 15 7 Connectors and PIN assignments 17 8 Accesories 18 9 Order guides 18 10 Appendix 19 11 Glossary 20 12 Warranty service 21 13 Disposal 21 14 Manufacturer contact 21 EDS H...

Page 8: ...nt measurement EDS supplies come with common floating ground to reduce the voltage noise level With up to 48 channels each single channel has an independent voltage control The modules are made of high precision components such as 24 bit ADC and 20 bit DAC and provide comprehensive security features By offering different configurations and options this module perfectly covers various types of appl...

Page 9: ...0 6 Vnom Resolution voltage measurement 1 2 10 6 Vnom Resolution current measurement 1 1 10 4 Inom 5 10 4 Inom Measurement accuracy The measurement accuracy is guaranteed in the range 1 Vnom Vout Vnom and for 1 year Accuracy voltage measurement 0 01 Vout 0 02 Vnom Accuracy current measurement 0 1 Iout 0 1 Inom 1 Iout 1 Inom Sample rates ADC SPS 5 10 25 50 60 100 500 2 Digital filter averages 1 16 ...

Page 10: ...1 kV 1 mA 48 5 2 R51 46 ED48y010x1050004300 SLA SLP EDS F1 30x 3 kV 500 µA 16 1 7 R51 46 ED161030x5040004300 SLA SLP EDS 18y 30x 3 kV 500 µA 24 2 6 R51 46 ED24y030x5040004300 SLA SLP EDS 30y 30x 3 kV 500 µA 48 5 2 R51 46 ED48ys030x5040004300 SLA SLP Notes 16 channel modules in standard only Table 2 Technical data Configurations of EDS series OPTIONS OPTION CODE EXAMPLE ITEM CODE HEX CODING POLARIT...

Page 11: ...ate controller the module will be used with The delivery condition is shown on the modules typeplate side plate of the module Typically newer iseg crate controllers CC24 CC23 CC238 are delivered with 250 kBits s standard Wiener M POD Controller and older iseg hardware is set on 125 kBit s standard bitrate INFORMATION INFORMATION EDS modules with Common Floating Ground CFG will be delivered with a ...

Page 12: ... 2 Inom The output voltage is limited to the specified value If the current exceeds the hardware current limit about 30 above the current limit value set by the limit potentiometer the channel will be shut off without delay and ramp In both cases the green LED on the front panel turns off 3 4 Safety Loop A safety loop can be implemented by the safety loop socket SL on the front panel and between t...

Page 13: ... the channel will be shut off without delay and ramp If the Delayed Trip function is activated the voltage ramp should be limited to 1 of Vnom before Higher values could trigger a trip by internal charge balancing during a ramp even though the output current does not exceed the set value Iset If the connected load contains capacities or if Iset is very small it might be necessary to further reduce...

Page 14: ...panel versions FRONT PANELS Channels 16 24 48 Floating CFG CFG HV Connector SHV S08 R51 Figure Table 5 Front panel versions EDS High Voltage Power Supply series Last changed on 17 06 2020 www iseg hv com 14 21 ...

Page 15: ...6 Dimensional Drawings Figure 2 Dimensional Drawing ex R51 EDS High Voltage Power Supply series Last changed on 17 06 2020 www iseg hv com 15 21 ...

Page 16: ...Figure 3 Dimensional Drawing ex SHV EDS High Voltage Power Supply series Last changed on 17 06 2020 www iseg hv com 16 21 ...

Page 17: ...nector contacts female ERA 05 403 ZLL1 Z592263 Contacts Safety Loop male FGG 2B 565 ZZC Z592261 Contacts Safety Loop female EGG 3B 665 ZZM Z592262 Socket Load Side SLA H51 LLZBG Z201035 SHV ROSENBERGER Socket 57S501 200N3 Connector 57K101 006N3 Z590162 S08 RADIALL Socket R317 580 000 Connector R317 005 000 Z592474 Safety Loop LEMO Socket ERA 0S 302 CLL Connector FFA 0S 302 CLAC Z592312 Limit monit...

Page 18: ...1 46 G 08 HV cable 6kV Kerpen SL v2YCeHI 56xAWG26 7red R51 46 A RG46_C07 LLL_RA46 SHV 04 HV cable shielded 30kV HTV 30S 22 2 open SHV_C04 LLL Notes 1 Length building examples 10cm 0 1 2 5m 2 5 12m 012 999m 999 Table 8 Guideline for cable ordering CONFIGURATION ORDER GUIDE item code parts ED 48 1 030 P 504 000 02 00 High Voltage Distributor Numbers of channels Class Vnom Polarity Inom nA Option hex...

Page 19: ...S MMS EDS iseg_datasheet_EDS_en pdf CAN EDCP Programmers Guide http download iseg hv com SYSTEMS MMS CAN_EDCP_Programmers Guide pdf iseg Hardware Abstraction Layer http download iseg hv com SYSTEMS MMS isegHardwareAbstractionLayer pdf EDS High Voltage Power Supply series Last changed on 17 06 2020 www iseg hv com 19 21 ...

Page 20: ... Inom nominal output current Iout output current Iset set value of output current Imon monitor voltage of output current Imeas digital measured value of current Itrip current limit to shut down the output voltage Iin input supply current Imax limit max value of output current Ilimit Current Limit Ibounds Current bounds a tolerance tube Iset Ibounds around Iset Pnom nominal output power Pin input p...

Page 21: ...rt rma 13 Disposal INFORMATION INFORMATION All high voltage equipment and integrated components are largely made of recyclable materials Do not dispose the device with regular residual waste Please use the recycling and disposal facilities for electrical and electronic equipment available in your country 14 Manufacturer contact iseg Spezialelektronik GmbH Bautzner Landstr 23 01454 Radeberg OT Ross...

Reviews: