3 Handling
3.1 Connection
The supply voltages and the CAN interface are connected to the module via a 96-pin connector on the rear side of the module.
The physical address of the module, determined by the slot position in the crate, is also accessible via this connector Modules
and crate controllers with different settings of bit rate do not work on the same CAN-Line.
INFORMATION
INFORMATION
Note: For proper operation the module must be configured with the correct CAN bitrate, which meets the
configuration of the crate controller, the module will be used with. The delivery condition is shown on the
modules typeplate (side plate of the module).
Typically newer iseg crate controllers (CC24, CC23, CC238) are delivered with 250 kBits/s standard.
Wiener M-POD Controller and older iseg hardware is set on 125 kBit/s standard bitrate.
INFORMATION
INFORMATION
EDS modules with Common Floating Ground (CFG) will be delivered with a jumper, which connects the
module-GND with the crate-GND. To operate in CFG configuration the jumper (CG-CFG) on the module back
must be removed, see Figure 1: Jumper configuration on back side.
Figure 1: Jumper configuration on back side
EDS High Voltage Power Supply series | Last changed on: 17.06.2020 |
www.iseg-hv.com
11/21