3.5.2 System connector H15 (EPS 3UC)
PIN
NAME
DESCRIPTION
VALUE
4
0V
(1
Supply ground
8
VREF
Internal reference voltage
5 V
(opt. 10V)
10
0V
(1
Supply ground
12
GND
(1
Signal ground
14
IMON
Monitor voltage of output
current
0 ... 5 V
(opt. 0 ... 10 V)
16
ON
HV ON/OFF
with voltage ramp
TTL-level:
LOW
➜
HV ON
HIGH or n.c.
➜
HV OFF
20
VSET
Set value of output voltage
0 ... 5 V
(opt. 0 ... 10 V)
24
VMON
Monitor voltage
0 ... 5 V
(opt. 0 ... 10 V)
26
VIN
Supply voltage
+24 V DC
28
ISET
Set voltage of output current
0 ... 5 V
(opt. 0 ... 10 V)
30
KILL_ENA
(2
Killenable, high active
TTL-level
32
INH
Inhibit,
LOW = active, shut down the
output voltage
TTL-level:
LOW
➜
HV OFF
HIGH or n.c.
➜
HV ON
Notes:
Case is connected to GND
1)
internally connected to GND
2)
If KillEnable is active the reaching or exceeding of the I
set
value will trigger a Kill-signal. This signal will switch off the HV
immediately without ramp.
Table 11: PIN Assignment H15 connector
EPS High Voltage Power Supply series | Last changed on: 2020-12-02 |
www.iseg-hv.com
23/36