3.2 Monitoring
3.2.1 Voltage
EPS 60W
The supply voltage and the internal auxiliary voltages of this high voltage supply are monitored. If one of these voltages is out of
the specified limits, the high voltage generation is stopped.
WARNING!
WARNING!
High voltage generation is reactivated immediately if the limit values are no longer exceeded.
For devices with option capacitor charger, the maximum output voltage value is monitored by the OVP (Over Voltage Protection)
comparator. The threshold is set to approx. 106 percent of nominal output voltage. If this threshold is reached (e.g. through an
internal defect), high voltage generation is stopped and an error register is set, which blocks the high voltage generation. To reset
the error register, the INHIBIT signal must be activated (set low).
EPS 150W
The supply voltage and internal auxiliary voltages of this high voltage supply are monitored for undervoltage and overvoltage. If
one of these voltages is out of the specified limits, the high voltage generation is stopped immediately and an error register is set
which also blocks the high-voltage generation after re-entering the normal operating range. To reset the error register, INHIBIT
must be activated (set to low).