Status Bit
Description when Bit is 1
Is Voltage Ramp Speed
Limited
Voltage ramp speed limitation caused by Kill Enable or Delayed Trip is active
Is Fast Ramp Down
All channels ramp down fast to zero due to power fail
Is Kill Enable
Module is in state Kill Enable
Is Temperature Good
Module temperature is in good conditions.
All channels will be turned off with ramp if the temperature becomes bad.
Is Supply Good
The external power supplies are all good (24 V ±10 % and 5 V ±5 %)
Is Module Good
Module in good state good, that means the condition Is No Sum Error AND NOT
(Event Temperature Not Good OR Event Supply Not Good OR Event Safety Loop Not Good) is
satisfied
Is Event Active
At least one Module Event Channel Status bit together with the corresponding Module Event
Channel Mask bit is set
Is Safety Loop Good
Safety Loop is closed.
If the safety loop is opened, all channels are shut down without ramp.
Is No Ramp
All channels are stable, no ramp is running.
Is No Sum Error
All channels are in good condition, that means the condition
(Is Voltage Limit OR Is Current Limit OR Is Current Trip OR Is External Inhibit OR
Is Voltage Bounds OR Is Current Bounds OR Is Arc Error) is zero for all channels
Is Input Error
An Input error occurred while accessing a module command or a channel outside the allowed
range.
Is Service
A hardware failure of the HV module has been detected. The HV will be switched off without a
possibility to switch on again. Consult the manufacturer.
Is Fine Adjustment
Fine adjustment is enabled for all channels
Is High Voltage On
At least one channel is actively generating High Voltage or has a measured voltage greater 60
Volt.
SCPI protocol common instruction set | Last changed on: 2020-10-07 |
www.iseg-hv.com
52/61