TH4330,4290,4260
68
ELECTRICAL SYSTEM
Battery
FIG. 6-31: Battery, 1, is located under engine hood in
front of instrument panel.
When battery removal, battery condition indicator check-
ing or cable cleaning is necessary, open the engine hood.
Keep top of battery clean and ensure cable connections
are clean and tight. Debris on battery can cause dis-
charge of battery and possible source of fire.
DAMGER: Batteries produce explosive
hydrogen gas when charged. Keep all sparks
and open flame away from battery.
When necessary to disconnect battery cables, always
disconnect the grounded (-) cable first to prevent short
circuits.
Batteries contain sulfuric acid electrolyte (fluid). Wear eye
and face protection. lf electrolyte comes in contact with
skin or clothes, wash immediately. Contact physician if
electrolyte is ingested or gets in eyes.
FIG. 6-32: Tractors are shipped with battery installed. If
battery replacement should become necessary, discon-
nect negative (-) cable, i, first and then remove positive
(+) cable, 2. Loosen and remove battery securing clamp
and carefully remove battery from Tractor.
When installing battery, cable, 2, connected to starter
solenoid should be connected to positive (+) battery ter-
minal first then cable, 1 , grounded to Tractor frame can
be connected to negative (-) battery terminal.
NOTE: Make sure replacement battery is of identical
size and equal capacity.
IMPORTANT: Do not reverse battery cable connections
as severe electrical system damage will
result.
FIG. 6-31
FIG. 6-32
Summary of Contents for TH4260
Page 72: ...TH4330 4290 4260 72 FIG 6 34 3 FIG 6 34 4 ...
Page 91: ...ISEKI TRACTOR 91 ...
Page 92: ...TH4330 4290 4260 92 ...
Page 93: ...WIRING DIAGRAM WIRING DIAGRAM WIRING DIAGRAM TH4260F ...
Page 94: ...WIRING DIAGRAM TH4260FH ...
Page 95: ...WIRING DIAGRAM TH4290F ...
Page 96: ...TH4330 4290 4260 WIRING DIAGRAM TH4290FH 4330FH ...