1. TECHNICAL FEATURES
2. ATLAS INSTALLATION
Connect to
192.168.0.184
from
Google Chrome,
Microsoft Edge
or Apple
Safari
Internet browser.
ATLAS DIN
Console
Battery
ON
Rese
t
W
ak
e u
p
Swit
ch O
FF
ON
GN
D
+5V
+V OU
T
O
UT
1
IN
1
GN
D
A
na
lo
g I
N
GN
D
+V
P
ow
er
GN
D
SE
R.
A
SE
R.
B
COM
NO
NO
COM
R
US
B
CH0
Relay
1
Relay
2
IN
2
IN
5
IN
3
IN
4
GN
D
+5V
R
1
R
3
LED
2
LED
1
R
2
R
5
R
4
+V
P
ow
er
GN
D
SE
R.
A
SE
R.
B
CH1
AUX
+V
P
ow
er
GN
D
SE
R.
A
SE
R.
B
CH2
Power IN
12 VDC - 800 mA
24 VDC - 400 mA
MADE IN ITALY
Lift up and remove
the white cover
1
Move the jumper on
Battery ON
2
Connect the power
supply (not included)
3
Check the green
Power IN LED is ON
4
Power
IN
Lockbus
channel
RS485
channels
Onboard
Relays
For future
developments
Color
Green
Red
Orange
Description
Power IN active
Switch OFF
Backup battery
pack operating
Orange
Orange
Orange
Orange
Ethernet activity
Serial Tx/Rx CH0
Serial Tx/Rx CH1
Serial Tx/Rx CH1
LED reference table
Ref.
ON
OFF
BATT
ETH
TX/RX
TX/RX
TX/RX
ON
OFF
BATT
ETH
TX/RX
TX/RX
TX/RX
Battery
ON
Connect the
Ethernet cable
5
Communication interfaces:
- 1 Ethernet interface TCP/IP 10/100 base
- 1 LOCKBUS channel (CH0) to connect Stylos online readers and Actuators
(max 8+8 for Atlas DIN and max 4 readers only for Atlas DIN PoE)
- 2 RS485 channels (CH1/CH2) to connect F9000 online readers (max 1 per
channel)
- 1 USB 2.0 Type A
- 1 serial interface (debug)
Power supply:
- 12÷24 Vdc o PoE
- Maximum power consumption 10W (with no connected devices)
PoE power supply:
- Requires PoE Switch IEEE 802.3af up to 15,4W
- Atlas DIN PoE absorbed power = 12W
- Delivery of data and power over CAT5e/CAT6 Ethernet cable
Internal Backup battery:
- 1500mAh (7,2Vdc) NiMH battery pack
- Estimated backup time: 30 minutes
CPU and memory:
- ARM 9 based CPU module
- 800MHz CPU clock
- 512MB Flash memory
- 64MB SDRAM
- 8GB Micro-SD
Onboard Relays (max 30V - 5A):
- Relay 1 = normally open (NO)
- Relay 2 = normally open (NO)
Operative system:
- Linux
Push buttons:
- Reset (to manually reboot the Atlas)
- Wake-up (to manually start the Atlas when OFF)
- Switch off (to manually switch off the Atlas)
Housing:
- DIN35 rail installation housing (white color)
- L x W x H = 160 x 90 x 60 mm (9 modules)
Environmental characteristics:
- Operating temperature: -10°C ÷ +50°C
- Storage temperature: -20°C ÷ +70°C
Conformity certifications:
- 2014/53/EU RED
- RoHS (electrical and electronic equipment).
- References standards: EN301 489-1, EN301 489-17, EN330 440,
EN60950-1, EN62209-2.
- For details see Declarations of Conformity available at iseo.com website
(download area).
Package contents:
- 1 Atlas Plus DIN Server for RFID and F9000 ON-LINE and OFF-LINE devices,
with connectors.
- Installation guide.