© International Scientific Group 2020
Version 2020.01
1. Introduction
The Viralair-UV air steriliser makes use of high-intensity ultraviolet germicidal lamp. This
method of disinfection is used to sterilise air indoors in the working environment.
2. Technical
1) Power supply: AC220V ± 22V; power frequency is 50HZ ± 1HZ.
2) Environmental parameters:
a) Ambient temperature: 5
℃
~
40
℃
;
b)
Relative humidity: ≤ 80%;
c) Atmospheric pressure: 800hpa
~
1060hpa.
3) Classified by electric shock protection. This product is Class II, Type B, general
equipment.
4) Disinfection space: ≤80m³;
5) Circulating
air volume: ≥800m³ / h;
6) UV leakage outside the unit
: ≤5µw / cm² (30cm away from the unit);
7) Noise: ≤55dB;
8)
Input power: ≤260W
3. Product Use
The UV air steriliser is suitable for indoor air disinfection in medical institutions,
production workshops with hygienic requirements, public places, offices, care homes
and domestic environments. There are many more applications. The unit does not
require operator attendance.
4. Operation
1. Close the doors and windows of the room to be disinfected.
2. Plug in the mains power lead and turn on at the rear of the unit. The power
indicator will light up and the unit will start to function.