7. Maintenance 

 

1.  Should the ultraviolet germicidal lamp intensity reduce or start to flicker the lamps will 

need replacing. 

2.  If the unit will not be used over a long period of time, unplug the power lead and 

protect from dust and contamination. 

 

3.  The unit should be cleaned with general purpose bacterial surface cleaner. 

 

8. Replacing UV Bulbs 

 

1.  Loosen the screws around unit and remove the outer casing 

2.  Remove the wire tie at the top of the UV bulb 

3.  Gently pull the old bulb upwards and out of the enclosure 

4.  Replace with new bulb and secure with the wire tie at the top 

5.  Replace the outer casing and secure with screws 

 
 

Note: discarded UV bulbs should be safely disposed of in accordance with waste disposal 

guidelines.

 
 

9. Warranty and repair 

 

1.  This UV air steriliser is supplied with a 12 month warranty from the date of purchase. 

 

2.  For  the  maintenance  and  replacement  of  parts,  please  contact  ISG  Fume  at 

sales@isgfume.com

 or 01366 385777. 

 
 

10. Transportation and storage 

 

Move the unit gently especially on uneven surfaces. The unit should be stored in a dry, 

well-ventilated, non-corrosive environment, and should not be stacked. 

 

 

 
 

 

International Scientific Group 

Unit 1, Karoo Close 

Bexwell Business Park 

Bexwell 

Norfolk 

PE38 9GA 

 

01366 385777 | sales@isgfume.com 

Summary of Contents for Viralair-UV

Page 1: ... International Scientific Group 2020 Version 2020 01 Viralair UV Steriliser User Manual ...

Page 2: ...ientific Group 2020 Version 2020 01 Content 1 Introduction 2 Technical 3 Product Use 4 Operation 5 Precautions 6 General Troubleshooting 7 Maintenance 8 Replace Bulbs 9 Warranty And Repair 10 Transportation And Storage ...

Page 3: ...is Class II Type B general equipment 4 Disinfection space 80m 5 Circulating air volume 800m h 6 UV leakage outside the unit 5µw cm 30cm away from the unit 7 Noise 55dB 8 Input power 260W 3 Product Use The UV air steriliser is suitable for indoor air disinfection in medical institutions production workshops with hygienic requirements public places offices care homes and domestic environments There ...

Page 4: ...nt of the unit through the air inlet vent This may cause damage to the fan and can result in electric shock 8 Avoid direct contact with liquid whilst operating 9 When repairing or cleaning ensured the power is turned off to prevent ultraviolet rays damaging the skin and eyes 10 The ultraviolet germicidal lamp should be replaced after 5000 hours of use 6 General troubleshooting Failure Action Unit ...

Page 5: ...enclosure 4 Replace with new bulb and secure with the wire tie at the top 5 Replace the outer casing and secure with screws Note discarded UV bulbs should be safely disposed of in accordance with waste disposal guidelines 9 Warranty and repair 1 This UV air steriliser is supplied with a 12 month warranty from the date of purchase 2 For the maintenance and replacement of parts please contact ISG Fu...

Reviews: