17 - 22
After the electrical connection is finished, tighten the cable gland (Fig.9) and fix the
cover. Then turn on the power and the lubrication indicator light (Yellow)(Fig. 11) on the
panel will lamp and the motor feeds oil if the electrical connection is correct.
YAE-A1/A1P1 is equipped with pressure regulator (Fig. 10) to adjust built-in pressure.
First loose the nut (2) and turn on the power. After the lubricant comes out from the pressure
relief valve, screw in the knob (1) until pressure build-in in the centralized lubrication system
per the user’s required pressure. Maximum built-in pressure regulating is limit to the
lubrication unit’s system pressure. If the user can’t regulate pressure, please check lubrication
connection where there is a leaking or the adapter is without check valve. After the user
complete built-in pressure regulating, tight the nut to fix the pressure regulator in case there is
any change by the accident.
3 General information
3-1 Control panel
Fig.11
3.2 Intermittence Time/ Lubrication Time Display
The setting of intermittent time and lubrication time can be adjusted by pressing any
of ”
▲
” or ”
▼
” for two seconds and read from value from the display. If no further
action, the timer will restart after 5 seconds.
Intermittence time display indicates the set value and the remaining of intermittent time
during the lubrication unit working. Lubrication time display indicates the set value and the
remaining of intermittent time during the lubrication unit working. When pressing any of
the ”
▲
” and ”
▼
” of Lubrication Time/ Intermittence Time for two seconds, the set-up
value will be shown. If no further action, the timer will restart after 2 seconds.
Increase of LUB. time
Decrease of LUB. time
f
d
l b i
i
Indicator light of INT. (Green)
Decrease of INT. time
Increase of INT. time
Indicator light of alarm (Red)
RES (Feed pushbutton)
Display of LUB. Time
Display of INT. Time
Indicator light of LUB.(Yellow)