18 - 22
3.3 Intermittence Time/ Lubrication Time set up
Press any of ”
▲
” or ”
▼
” for two seconds and then enter time setting mode by
pressing ”
▲
” or ”
▼
”to adjust time from 1 to 999 for interval and lubricating.
Continuously press ”
▲
” or ”
▼
”to fast increase or decrease value. During time setting
mode, two indicators will spark in the same time.
Time unit for intermittence is minute ; Time unit for lubrication is second.
If no further action, the timer will restart after 5 seconds and run with new setting. The
lubrication indicator is light and intermittence indicator is dark during lubricating. On the
contrary, the intermittence indicator is light and lubrication indicator is dark at the interval.
3-4 RES button
Press RES button (Fig. 11) for two seconds, the lubrication unit will restart up and then
run default setting to deliver lubricant.
3-5 Operating mode setting
Warning !!
Only allow authorized person by iSHAN company to change default setting. The
user only can adjust time for lubrication or intermittence.
3-5.1 Display & Action instruction
Action
Indicator light
of LUB.
Indicator light
of INT.
Indicator light
of Alarm
Alarm Motor
Monitor
unit
Cycle mode
ON
OFF
OFF
ON
(Convey oil)
OFF
Time unit
1 second
Flashing
per 1 sec.
Flashing
per 1 sec.
OFF OFF
ON
(Convey oil)
OFF
Time unit
1 minute
Flashing
per 2 sec.
Flashing
per 2 sec.
OFF OFF
ON
(Convey oil)
OFF
Time unit
1 hour
Flashing
per 5 sec.
Flashing
per 5 sec.
OFF OFF
ON
(Convey oil)
OFF
Setting time
unit
Flashing Flashing OFF
Beep
OFF OFF
Time setting
Flashing Flashing OFF
Beep
OFF OFF
No pressure
build-up
Flashing
per 0.5 sec.
OFF
Flashing
per 0.5 sec.
ON OFF ON
Insufficient oil
OFF
Flashing
per 0.5 sec.
Flashing
per 0.5 sec.
ON OFF ON
Press RES button 2 seconds / ON
OFF OFF
OFF
2 seconds / ON
OFF