BC-3000
•
Service Manual
•
Rev. 1
3 - 5
Chapter 3. Parts Disassembly & Replacement
5. Remove the upper case.
1)
Lower the side panel in the direction of the
arrow.
2)
Cut the seal wire, and remove the seal wire
screws.
3)
Remove the four screws which secure the
upper case, then carefully lift the cover off
the main body.
CAUTION!
After the base seal wire has been cut, it is necessary to have the scale re-inspected and the seal replaced.
Never cut the base seal unless required.