99
Data Send/Load (C99)
Data Send/Load is used for data communication with an IF-21FD interface unit.
Preparation
Before attempting to transmit data, make sure the BC-3000 is connected to the IF-21FD unit, and the scale
and IF-21FD power switches are ON.
1) All IF-21FD operations are performed from the BC-3000.
2) Before using a new floppy disk perform step 99-03 to format the disk.
(Use 2DD type disk only).
1. Transfer File (C99-02)
Transfer File is used to transmit individual data
files.
1.1 Select IF-21 file No. (C99-02-01)
Enter the number corresponding to the desired
file number (1 to 8), then press
ENTER
1) Press
→
to see which files have been used previously.
2) Connect IF-21FD to the BC-3000 using the 9-pin cable supplied with the IF-21FD recorder.
3) Set IF-21FD DIP switches 2 and 5 down, all others are up.
4) For communications error codes, see chapter S6.
ENTERED
NUMBER
FILE
NUMBER
Note:
Note:
C99-02-01
No 0
0
Summary of Contents for BC-300
Page 1: ...SERVICE MANUAL Manual No 0141A ISHIDA CO LTD Retail Scale BC 3000 48775 ...
Page 4: ...HARDWARE SECTION ...
Page 5: ...BC 3000 Service Manual Rev 1 1 1 Chapter 1 Introduction 1 INTRODUCTION 1 1 MAIN COMPONENTS ...
Page 32: ...6 4 BC 3000 Service Manual Rev 1 Chapter 6 Troubleshooting ...
Page 33: ...SOFTWARE SECTION ...
Page 62: ...APPENDIX ...
Page 63: ...BC 3000 Service Manual Rev 1 Appendix 1 Appendix A1 DC DC Converter Unit Schematic Diagram ...
Page 64: ...Appendix 2 BC 3000 Service Manual Rev 1 Appendix ...
Page 65: ......
Page 69: ...Appendix 8 BC 3000 Service Manual Rev 1 Appendix Sample Labels ...
Page 71: ...Appendix 10 BC 3000 Service Manual Rev 1 Appendix Sample Labels ...