Manual No. 085-3435-07
25/45
IGB/IGX Series (Overseas Specifications) Service Manual
Address Item Data
Range
Remarks
101
100A and 100B check data
(Writing twice)
-
102A
Selection of ON/OFF key function (bit 0)
Selection of Preset auto call-up function (bit 1)
Selection of 16/24 digit printer (bit 2)
Selection of Date print function (bit 3)
0 to 1 (F1)
0 to 1 (F2)
0 to 1 (F3)
0 to 1 (F4)
Data set in Setup
Mode of Operation
Manual.
102B
Selection of Preset No. print function (bit4)
Selection of single/consecutive chit print (bit5)
Selection of Tare amount print function (bit6)
Selection of Upper/Lower limits print function (bit7)
0 to 1 (F5)
0 to 1 (F6)
0 to 1 (F7)
0 to 1 (F8)
Reference
Reference
Refer to IGB/IGX
Operation Manual.
103A
Baud rate setting (bit 0 to 3)
0 to F (F9)
103B
Output message specification (bit 4 to 7)
0 to F (F10)
104A
Data output method (bit 0 to 3)
0 to F (F11)
104B
Data output condition (bit 4 to 7)
0 to F (F12)
105A
Contact output signal setting (bit 0 to 3)
0 to F (F13)
105B
Contact input signal setting (bit 4 to 7)
0 to F (F14)
106A
High-level buzzer output setting (bit 0 to 3)
0 to F (F15)
106B
Built-in buzzer selection function (bit 4 to 7)
0 to F (F16)
107A
Automatic power off setting (bit 0 to 3)
0 to 6 (F17)
107B Reserved
108 to 109 Check sum from 102 to 107
-
110 to 115 Weighing condition setting data
Refer to Weighing
condition setting table.
116A
Country code (Refer to Country code table)
0 to F
(Default 10: Japan)
116B Reserved
0
117A Reserved
0
117B Reserved
0
118 to 120 A/D zero point data (adref)
24 bit
121 to 123 A/D calibration data (adwidth)
24 bit
124
Weighing capacity setting (Refer to Capacity setting
table)
00 to 99
(Default 1: 60kg)
125A
JAPAN only
0 to F
125B
Span adjusted flag
5H or others
5H=OK
Others=Error
126, 127
Check sum from 100 to 113.
-