ALERT SYMBOLS

 

The following symbols are used to alert service personnel of potential danger or special 
circumstances related to the safe and proper servicing of this machine.

 

 

Precautions which must be followed to prevent the possibility of death or 
serious injury. 

 

Precautions which must be followed to prevent the possibility of light or 
moderately severe injury to personnel or damage to the machine. 

 
 
 
 
 
 

page iv   

INS-100 Operator’s Manual    No. IW05XINS-100A 

Summary of Contents for INS-100

Page 1: ...T Do not carry out installation operation service or maintenance until thoroughly understanding the contents of this manual Keep this manual available at all times for installation operation service and maintenance INS 100 Operator s Manual No IW05XINS 100A ...

Page 2: ...Copyright 2005 by Ishida Co Ltd All Rights Reserved No part of this manual may be reproduced in any form by mimeograph or any other means without written permission of the publisher ...

Page 3: ...ding provision by qualified service personnel Disconnect power supply before servicing when using AC power To ensure your personal safety disconnect the power supply before servicing Do not remove covers or enclosures To avoid personal injury and shock do not open or remove any covers or enclosures of the instrument unless specified in the manual Do not perform unspecified maintenance For your own...

Page 4: ...o come into contact with the machine fDo not drop or apply a strong shock to the machine fWhen cleaning the machine only use a soft dry cloth or a cloth wetted with a neutral cleanser Never use thinner or other volatile liquids page ii INS 100 Operator s Manual No IW05XINS 100A ...

Page 5: ...ight Areas where water or other liquids are easily spilled on the machine Areas subject to excessive vibration or unstable surfaces Areas exposed to direct cold air Areas subject to low temperatures Areas subject to a lot of dust or dirt Areas with large voltage fluctuations Areas where the scale is not level INS 100 Operator s Manual No IW05XINS 100A page iii ...

Page 6: ... to the safe and proper servicing of this machine Precautions which must be followed to prevent the possibility of death or serious injury Precautions which must be followed to prevent the possibility of light or moderately severe injury to personnel or damage to the machine page iv INS 100 Operator s Manual No IW05XINS 100A ...

Page 7: ...UPPLY 4 1 4 SPECIFICATIONS 5 Chapter 2 WEIGHING OPERATIONS 7 2 1 LEVEL ADJUSTMENT 8 2 2 POWER ON OFF 9 2 2 1 POWER ON 9 2 2 2 POWER OFF 9 2 3 TARE SUBTRACTION 10 2 3 1 WEIGHING TARE 10 2 3 2 KEYBOARD TARE 11 2 4 WEIGHING SINGLE COMMODITY 12 2 5 WEIGHING SINGLE COMMODITY WITH TARE 14 2 6 RANDOM WEIGHING ADDITIONS 16 2 7 RANDOM WEIGHING ADDITIONS WITH TARE 19 2 8 TROUBLE SHOOTING 23 INS 100 Operator...

Page 8: ...page vi INS 100 Operator s Manual No IW05XINS 100A ...

Page 9: ...PRODUCT OVERVIEW 1 INS 100 Operator s Manual No IW05XINS 100A page 1 ...

Page 10: ... when tare weight is memorized ZERO Lights when weight value is zero AC Lights when AC power is supplied LOW BATT Lights when the battery level becomes low TOTAL Lights when totals are added STABLE Lights when scale is in stable condition page 2 INS 100 Operator s Manual No IW05XINS 100A ...

Page 11: ...ric data CLEAR Used to clear numeric entries ON OFF Used to turn scale ON OFF not electrical power switch ZERO Used to adjust scale to zero TARE Used to engage disengage tare subtraction operation ADD Used to add totals EURO Used to change currency INS 100 Operator s Manual No IW05XINS 100A page 3 ...

Page 12: ... This machine can also be operated by AC power supply Use the specified AC voltage after referring to the specification plate located on the machine Insert the electrical plug into the same rated AC outlet To disconnect the power supply remove the electrical plug from the electrical outlet page 4 INS 100 Operator s Manual No IW05XINS 100A ...

Page 13: ...r weighing capacity 15kg 3 998kg for weighing capacity 6kg Power Supply Rechargeable Sealed Lead Acid Battery or AC220V 10 15 50Hz Operating Temperature 10 C 40 C Size 335 L x 310 W x 120 H mm 372 L x 310 W x 402 H mm with pole display Weight Approx 3 5kg excluding Battery Approx 4 7kg excluding Battery with pole display INS 100 Operator s Manual No IW05XINS 100A page 5 ...

Page 14: ...page 6 INS 100 Operator s Manual No IW05XINS 100A ...

Page 15: ...WEIGHING OPERATIONS 2 INS 100 Operator s Manual No IW05XINS100 A page 7 ...

Page 16: ...le on a stable counter top or other flat surface Rotate the four adjustment feet until the level s bubble is aligned in the center of the circle This indicates that the machine is level page 8 INS 100 Operator s Manual No IW05XINS100 A ...

Page 17: ...t after all digits flashes on the display for a while Note 1 If the ZERO indicator is not lit press the ZERO key to turn on the indicator Note 2 The AC indicator is lit when an AC power is used d When using AC power When using DC power 2 2 2 POWER OFF To turn OFF the machine press the ON OFF key INS 100 Operator s Manual No IW05XINS100 A page 9 ...

Page 18: ...ld display ZERO with nothing on the weigh platter Should the scale does not display ZERO press the ZERO key to perform zero adjustment 2Loading Actual Tare Place a tare on the weigh platter and press the TARE key to save tare setting The TARE indicator will light up Note Items weighing less than previous tare setting cannot be calculated In that case it is necessary to reset tare value by pressing...

Page 19: ... not display ZERO press the ZERO key to perform zero adjustment 2Keyboard Tare With nothing loaded on the weigh platter use numeric keys to enter data and press the TARE key to save tare setting The TARE indicator will light up Note Keyboard tare operation may be prohibited in some countries due to Weights and Measures Regulations Example Tare weight 75g d d d INS 100 Operator s Manual No IW05XINS...

Page 20: ...g on the weigh platter Should the scale does not display ZERO press the ZERO key to perform zero adjustment 2Unit Price Key in the unit price using the numeric keys Example Unit price 4 50 d 3Placing Commodity Place a commodity on the weigh platter The weight and price will appear on the display Example Commodity weight 275g d page 12 INS 100 Operator s Manual No IW05XINS100 A ...

Page 21: ...y Remove the commodity from the weigh platter The unit price is stored until a new value is keyed in d 5Clearing Unit Price To clear the unit price press the CLEAR key d INS 100 Operator s Manual No IW05XINS100 A page 13 ...

Page 22: ...ress the ZERO key to perform zero adjustment 2Saving Tare Weight Use either Weighing Tare or Keyboard Tare to save tare setting Refer to Section 2 3 The TARE indicator will light up 3Unit Price Key in the unit price using the numeric keys Example Unit price 4 50 d 4Placing Commodity Place a commodity on the weigh platter The weight and price will appear on the display Example Commodity weight 300g...

Page 23: ... and tare weight are stored until new values are keyed in d 6Clearing Unit Price To clear the unit price press the CLEAR key d 7Clearing Tare Weight To clear the tare weight press the TARE key The TARE indicator will disappear d INS 100 Operator s Manual No IW05XINS100 A page 15 ...

Page 24: ...eigh platter Should the scale does not display ZERO press the ZERO key to perform zero adjustment 2Unit Price Key in the unit price using the numeric keys Example Unit price 4 50 d 3Placing Commodity Place a commodity on the weigh platter The weight and price will appear on the display Example Commodity weight 275g d 4Adding Totals Press the ADD key to add totals The TOTAL indicator will light up ...

Page 25: ...t Price Key in the unit price for the next commodity using the numeric keys Example Unit price 6 50 d 7Placing Next Commodity Place the next commodity on the weigh platter The weight and price will appear on the display d INS 100 Operator s Manual No IW05XINS100 A page 17 ...

Page 26: ... price for two commodities will appear on the display d 9Removing Commodity Remove the commodity from the weigh platter d 10Clearing Totals To clear totals press the CLEAR key The TOTAL indicator will disappear and the initial display appears d page 18 INS 100 Operator s Manual No IW05XINS100 A ...

Page 27: ...scale does not display ZERO press the ZERO key to perform zero adjustment 2Saving Tare Weight Use either Weighing Tare or Keyboard Tare to save tare setting Refer to Section 2 3 The TARE indicator will light up 3Unit Price Key in the unit price using the numeric keys Example Unit price 4 50 d 4Placing Commodity Place a commodity on the weigh platter The weight and price will appear on the display ...

Page 28: ...mmodity from the weigh platter d 7Clearing Tare Weight To clear tare weight press the TARE key The TARE indicator will disappear d 8Saving Tare Weight Use either Weighing Tare or Keyboard Tare to save tare setting Refer to Section 2 3 The TARE indicator will light up page 20 INS 100 Operator s Manual No IW05XINS100 A ...

Page 29: ... weigh platter The weight and price will appear on the display Example Commodity weight 490g d 11Adding Totals Press the ADD key to add totals The TOTAL indicator will light up and the total price for two commodities will appear on the display d 12Removing Commodity Remove the commodity from the weigh platter d INS 100 Operator s Manual No IW05XINS100 A page 21 ...

Page 30: ...AR key The TOTAL indicator will disappear The tare weight is stored until a new value is keyed in d 14Clearing Tare Weight To clear the tare weight press the TARE key The TARE indicator will disappear d page 22 INS 100 Operator s Manual No IW05XINS100 A ...

Page 31: ...cale there are no displays but buzzer sounds continuously Check the weigh platter is mounted on scale correctly Check that no objects are touching the weigh platter from above side or below Scale is out of calibration due to overload or shock load contact service representative Reading weight is unstable Check that no objects are touching the weigh platter from above side or below Check that scale...

Page 32: ...44 SANNO CHO SHOGOIN SAKYO KU KYOTO 606 8392 JAPAN PHONE 81 75 771 4141 FACSIMILE 81 75 751 1634 URL http www ishidajapan com Design and specifications are subject to change without notice ...