Chapter 3 TEST MODE
3-16
IP-EMZ Service Manual
Buttons/Display Fields
Function
Head Resistance
Displays thermal head resistance (
Ω
, zero suppression).
Touch the [SET] button after numeric entry to set new head resistance.
Data range is 0-999.
The buzzer will sound if data is set beyond the specified range.
Touch the [SET] button without numeric entry to automatically set head
resistance.
“Auto Setting” is displayed during the execution of automatic settings.
Head Error Check
Execute thermal head error check.
“Processing” is displayed during processing.
“Normal” is displayed when processing has ended normally.
“Abnormal” is displayed when processing has ended abnormally.
Memory Initialization
Initialize printer memory.
“Processing” is displayed during processing.
“Normal” is displayed when processing has ended normally.
“Abnormal” is displayed when processing has ended abnormally.
Execute sensor levels, back feed calibration, initialization of the protection
setting value against head temperature rise, and acquisition of the head
resistance, and initialization of label and cassette master data for the selected
printer.
Be sure to execute this procedure when the P-910 has been replaced.
Head Type
Displays thermal head type name.
One of the following three types can be set:
Press the [SET] button after numeric entry to set the desired head type.
Default data: “0” LH4114 (8 dots/mm standard).
1: LH4116
(8 dots/mm history control). Printing is not possible with the
LH4116 head (8 dots/mm history control) installed. Printing can be
normally performed when “1” is set and the LH4114 installed.
2: BHP4312 Set the BHP4312 (8 dots/mm 2 colors) when using two color
specifications. Set the DIP switch on the thermal board and "Thermal
paper type" in “Print Adjustment 2/2” screen to “2: 2 color label”.
Usage Distance
Thermal head movement distance (“km”, zero suppression) is displayed.
Touch the [SET] button to clear head movement distance.
Cassette Status
Refer only when adjusting the cassette applicable printer.
{{{{
: No cassettes are inserted.
{{{z
: Cassette 1 is inserted.
The same sensor as [Head Up Sensor] is used.
Head Up Sensor
Displays head status.
“ON” is illuminated when the head is set normally.
“OFF” is illuminated when the head is up.
Label Sensor Level
Displays label sensor level.
Touch this button to finely adjust the label sensor level (display field will
change to green) and press the (
UV
) adjustment buttons. Touch this button
again to change the display to white and set adjustment data. The level range
is 0-255.
Peel Sensor Level
Displays peel sensor level.
Touch this button to finely adjust the peel sensor level (display field will
change to green) and press the (
UV
) adjustment buttons. Touch this button
again to change the display to white and set adjustment data. The level range
is 0-255.
Summary of Contents for IP-EMZ
Page 13: ...Chapter 1 INSTALLATION IP EMZ Service Manual 1 5 1 3 OUTER DIMENSIONS Unit mm ...
Page 24: ...Chapter 2 SETUP MODE 2 6 IP EMZ Service Manual Text Edit After Screen Text Edit Packed Screen ...
Page 47: ...Chapter 2 SETUP MODE IP EMZ Service Manual 2 29 ...
Page 79: ...Chapter 3 TEST MODE 3 32 IP EMZ Service Manual ...
Page 88: ...Chapter 4 SYSTEM MODE IP EMZ Service Manual 4 9 System Data Setup Screen 2 ...
Page 96: ...Chapter 4 SYSTEM MODE IP EMZ Service Manual 4 17 Label Content Selection Pop up Screen ...
Page 120: ...Chapter 4 SYSTEM MODE IP EMZ Service Manual 4 41 Restoration Confirmation Screen ...
Page 141: ...Chapter 4 SYSTEM MODE 4 62 IP EMZ Service Manual ...
Page 151: ...Chapter 6 ELECTRIC ASSEMBLY 6 2 IP EMZ Service Manual 6 1 ELECTRIC BLOCK DIAGRAM ...
Page 172: ...APPENDIX A LABEL FORMATTING IP EMZ Service Manual A 3 Label format table No 99 For receipt ...