Chapter 3 TEST MODE
IP-EMZ Service Manual
3-17
STANDARD VALUE
STANDARD VALUE can perform change of the threshold value of label
sensor and peel sensor.
Default: 0
Default: 90
LABEL SENSOR STD VALUE
The initial value of the threshold value of a label sensor is 0.
Level Detection mode:
0 STD judges the difference of the Sensor output level, of label and label gap.
In the case of 60 or more, a level difference judges it as a label gap.
Threshold Detection mode:
In the case of one (1) or more, STD considers it as the value of threshold.
If the value of threshold is exceeded, it will be judged as a label gap.
PEEL SENSOR STD VALUE
Only Threshold Detection mode:
It is judged that the value below threshold has a label.
It is judged that the value exceeding threshold has no label.
DPM
DIGITAL POTENTIAL METER
Digital The position of volume can be checked.
It is a minimum 0 from a maximum 255.
The following figure is a case where it transposed to analog type volume.
Summary of Contents for IP-EMZ
Page 13: ...Chapter 1 INSTALLATION IP EMZ Service Manual 1 5 1 3 OUTER DIMENSIONS Unit mm ...
Page 24: ...Chapter 2 SETUP MODE 2 6 IP EMZ Service Manual Text Edit After Screen Text Edit Packed Screen ...
Page 47: ...Chapter 2 SETUP MODE IP EMZ Service Manual 2 29 ...
Page 79: ...Chapter 3 TEST MODE 3 32 IP EMZ Service Manual ...
Page 88: ...Chapter 4 SYSTEM MODE IP EMZ Service Manual 4 9 System Data Setup Screen 2 ...
Page 96: ...Chapter 4 SYSTEM MODE IP EMZ Service Manual 4 17 Label Content Selection Pop up Screen ...
Page 120: ...Chapter 4 SYSTEM MODE IP EMZ Service Manual 4 41 Restoration Confirmation Screen ...
Page 141: ...Chapter 4 SYSTEM MODE 4 62 IP EMZ Service Manual ...
Page 151: ...Chapter 6 ELECTRIC ASSEMBLY 6 2 IP EMZ Service Manual 6 1 ELECTRIC BLOCK DIAGRAM ...
Page 172: ...APPENDIX A LABEL FORMATTING IP EMZ Service Manual A 3 Label format table No 99 For receipt ...