Chapter 3 TEST MODE
3-20
IP-EMZ Service Manual
3. The adjustment STD value(Threshold Detection mode)
Press the [FEED] key 2 or 3 times. Then, label comes
out.
Press the [2][0][0][0] at numeric keys. And press the
[PRESET] key. Then, graph pops up.
Touch the [STD VALUE] button.
Enter the “STD Preset value” at numeric keys, and
touch the [LABEL SENSOR STD VALUE] field.
Next, please display Graph pops and check the line
of STD VALUE Line.
FEED
A
is the value between label detection part
and label gap detection part.
Label detection part is the highest value.
Label gap detection part is the lowest value.
Preset value is between one half of
A
, and
2/3.
STD Preset value
A
2/3
1/2
PRESET
2
0
0
0