Manual No. 0158A
25/68
IWB
−
IWX Series (Overseas Use) Service Manual
Address Weight
Item
Data
112A
-
Starting range
0: ±1/50 of weighing capacity (±2%)
1: ±1/25 of weighing capacity (±4%)
2: ±1/10 of weighing capacity (±10%)
3: ±1/7.5 of weighing capacity (±13.3%)
4: ±1/6 of weighing capacity (±16.6%)
5: ±1/5 of weighing capacity (±20%)
6: ±1/4 of weighing capacity (±25%)
7: ±1/3 of weighing capacity (±33.3%)
8: ±1/2 of weighing capacity (±50%)
9
∼
Not available
112B
-
Stabilized, re-
stabilized frequency
0
∼
15 times.
113A
-
Stabilized/re-
stabilized range
n=0
∼
15 (
±
n/10 e )
113B
-
Re-stabilization
starting range
n=0
∼
15 (
±
n/10 e )
1
Zero point mark
0: Lights on at true zero, 1: Lights on at provisional zero
2
Over-scale indication 0: BLANK
1: “OL”
4
Below true zero
indication
0: “
_____
”
1: Negative value
114A
8
Decimal point
indicator
0: “.”
1: “,”
1
Over-scale range
0: Indication up to +9e 1: Indication up to +3e
2
Tare subtraction
0: Possible
1: Not possible
4
Clearing tare weight
by pressing ZERO
key
0: No
1: Yes
114B
8
Zero suppress
function (at multiple
range spec.)
0: Available
1: Not available
1
Input value/preset
tare weight
subtraction and
preset unit weight
function
0: Available
1: Not available
2
Zero tracking
0: Available
1: Not available
4
Micro weight follow-
up
0: Available
1: Not available
115A
8
Unstable range
0: ±0.5e
1: ±20e
1
Number of PLU,
and PLU display
(IWB only)
0: 10 items
1: 5 items
Display available
Display not available
2
Stable indication
(IWB only)
0: “
∗
” indication
1: “
W
“ cursor indication
4
Weight unit cursor
indication
0: Normally lighting
1: Lighting only when “non
switching” is set.
115B
8
Reserve