Manual No. 0158A
66/68
IWB
−
IWX Series (Overseas Use) Service Manual
2) 1: DAP-01 format
Character
Polarity
Weight value
(Quantity number)
Unit
Scale
status
Excess/appr
opriate/short
CR
LF
Volume in
byte
1
7
2
1
1
1
1
14 bytes
Output with floating point
[Decimal point is fixed “.”
(2EH)]
H (48H): Weight exceeding upper limit.
g (47H): Weight within the range.
L (4CH): Weight short to lower limit.
SP (20H): Other.
+ (2BH): Weight value positive
−
(2DH): Weight value negative
S (53H): Weight value is stable.
U (55H): Weight value is unstable.
E (45H): Weight value is over the scale or error.
CR=0DH
LF=0AH
Kg (6BH, 67H): kg
g (20H, 67H): g
lb (6CH, 62H): lb
oz (6FH, 7AH): oz
ps (70H, 73H): pcs
3) 2: IWQ 1 format
Character
Preset
No.
Pola-
rity
Weight value
(Quantity number)
Unit
Scale
status
Excess/appro-
priate/short
CR
LF
Volume in
byte
4
1
7
2
1
1
1
1
18 bytes
Output with float-
ing point
[Decimal point is
fixed “.” (2EH)]
H (48H): Weight exceeding upper limit.
g (47H): Weight within the range.
L (4CH): Weight short to lower limit.
SP (20H): Other.
+ (2BH): Weight value
positive
−
(2DH): Weight value
negative
S (53H): Weight value is stable.
U (55H): Weight value is unstable.
E (45H): Weight value is over the scale or error.
CR=0DH
LF=0AH
Kg (6BH, 67H): kg
g (20H, 67H): g
lb (6CH, 62H): lb
oz (6FH, 7AH): oz
ps (70H, 73H): pcs