14
IWQ Operation Manual Kg Version
Manual No. 0142A
3. Key in the Lower Limit Weight. (if necessary)
After keying in the lower limit weight, press the
key.
The upper and lower limit weights can also be
set by calling preset values. To change a pre-
set value temporarily, key in a new value and
then press the
key or
key.
To reset the input, enter "0" and then press the
or
key. (Operation: Ref., 6-2 Call-
ing a Preset Value)
• For a lower limit weight of 10.00 kg
4. Weigh an Item.
Place the item to be weighed on the weighing platter together with the tare weight.
• For a 10-kg bag of rice
Weighing
result
Weighing condition
Indication on scale
Over
Weight > upper limit weight
Upper limit weight indi-
cator flashes.
OVER indicator lamp
(orange LED) lights.
Under
Weight < lower limit weight
Lower limit weight indi-
cator flashes.
UNDER indicator lamp
(red LED) lights.
ACCEPT
Lower limit weight
≤
weight
≤
upper limit weight
---
ACCEPT indicator lamp
(green LED) lights.