53/54
IWQ Series Service Manual
•
Contact BOX in linked operation (Optional)
Phenomenon
Cause
Measure
•
Confirm set value of Setup Mode
F13/F14.
1.Contact output signal is
not correctly set.
Reference
Reference
Refer to the Setup
Mode list.
2.Insufficient conductivity
at contacts.
•
Check the main board XJ1
connector and I/F board XJ3
connector for contacts or
disconnection.
1. No output (OUT1
−
OUT4) or
incorrect operation.
Contact input (IN1) is not operating
either.
3.Board-related defect.
•
Replace the I/F board.
•
Replace the main board.
•
Loud buzzer (Optional)
Phenomenon
Cause
Measure
•
Check set value of Setup Mode
F15.
1. Incorrect setup.
Reference
Reference
Refer to the Setup
Mode list.
2. Insufficient conductivity
at contact.
•
Check the XJ4 connector and
harness C2 RS232C for contact
or disconnection.
•
Check for contacts or
disconnection of the cable
coming from the loud buzzer.
1. Buzzer is not sounding.
3. Board-related defect.
•
Replace the main board.