Manual No. 0149A
IWX Operation Manual Kg Version
27
Setting
No.
Description of setting
Setting
value No.
Setting condition
F11
Serial output system (RS232)
00
No output function provided
01
Unconditional (synchronized with A/D conversion)
02
Under output condition <F12>
03
When data input is required (RS input)
F12
Serial output condition
(RS232)
00
Automatic/within limit/stable state output (printing)
01
Manual/within limit/ stable state output (printing)
02
Automatic/within and without limit/ stable state output
(printing)
03
Manual/within and without limit/ stable state output
(printing)
04
Automatic/within limit/zero-return output (printing)
05
Manual/within limit/zero-return output (printing)
06
Automatic/within and without limit/zero-return output
(printing)
07
Manual/within and without limit/zero-return output
(printing)
F13
Setting connector output
signal (connector box)
00
1. Stable 2. Zero-point marking 3. OK 4. Over
01
1. Stable 2. Zero indication 3. OK 4. Over
02
1. Stable 2. Zero indication 3. OK 4. Outside limit
03
1. Stable 2. Under 3. OK 4. Over
04
1. Under tare subtraction 2. Under 3. OK 4. Over
F14
Setting connector input signal
(connector box)
00
key
01
key
02
key
F15
Loud buzzer (only when
installed optionally)
00
Buzzer ON simultaneously with built-in buzzer (normally
OFF)
01
Buzzer ON under "OVER" condition (normally OFF)
02
Buzzer ON under "OK" condition (normally OFF)
03
Buzzer ON under "UNDER" condition (normally OFF)
04
Buzzer ON when weighing is stabilized (normally OFF)
05
Buzzer ON when weighing is stabilized under "OVER"
condition (normally OFF)
06
Buzzer ON when weighing is stabilized under "OK"
condition (normally OFF)