10
Uni-3 Technical Manual
1.3.10 Save File to Flash Drive
USB specifications: 8GB or smaller, FAT32 format, USB 3.0
Use the following steps to save files to a flash drive.
1. Remove Speed Key insert page.
2. Insert a flash drive.
3. Enter
6000
then press
Mode
.
B00 SETUP
will display.
4. Enter the password 495344 then press
PLU
to enter service level.
B00 SETUP
will display.
5. Enter
27
then press the
Down Arrow
, then press
Enter
.
B27-01
USB-TO-SCALE
will display.
6. Press the
Right
Arrow
then press
Enter
.
B27-02-01 O/P SELECT
will display.
7. Press
PLU
.
B27-200 SEL USB FOLDER
will display.
8. Press the
Down
Arrow
to select an empty folder.
B27-20x USB DATA 0x
will display.
9. Press
Edit
to name folder.
InP 0001
will display.
10. Type in folder name. Press
Enter
.
B27-02
SCALE-TO-USB
will display.
11. Press
3
then press the
Down Arrow
.
B27-02-03
MASTER MODE
will display.
12. Enter
1
for Auto or
2
for Manual send. Press
Enter
.
B27-02-03
Master Mode (with selected load choice)
will
display.
13. Press
Enter
.
B27-02-04
EXECUTE
will display.
14. Press
Zero
.
14012-0000
OUTPUT CHECK
will display.
15. Press
Enter
to begin sending file to USB.
14014-0000
COMPLETE
will display when complete.
16. Press
Enter
then press
Mode
three times to exit Setup Mode.
KEY IN ITEM No.
will display.
17. Remove the flash drive. Scale is ready to resume weighing and labeling.
1.3.11 Set Product Name Display Timer
Use the following steps to set the product name display timer.
1. Remove Speed Key insert page.
2. Enter
6000
then press
Mode
.
B00 SETUP
will display.
3. Enter the password 495344 then press
PLU
to enter service level.
B00 SETUP
will display.
4. Enter
17
then press the
Down Arrow
then press
Enter
twice.
B17-01-02 OPEN PLU
will display.
5. Enter
4
then press the
Down Arrow
.
B17-01-05 SEG PLU
will display.
6. Enter
2
then press
Enter
three times.
B17-01 CALL
will display.
7. Enter
2
then press the
Right Arrow
, then press
Enter
.
B17-03-01 REG TMR
will display.
8. Enter
4
then press the
Down Arrow
.
B17-03-07 SEG PLU TIMER
will display.
9. Enter
3
then press
Enter
.
B17-03-07 SEG PLU TIMER
will display.
10. Press Mode three times to exit Setup Mode.
KEY IN ITEM No.
will display. Scale is ready to resume
weighing and labeling.
Note